Pregled bibliografske jedinice broj: 1248222
Silicon foil patching for blast tympanic membrane perforation: a retrospective study
Silicon foil patching for blast tympanic membrane perforation: a retrospective study // Croatian medical journal, 60 (2019), 6; 503-507 doi:10.3325/cmj.2019.60.503 (međunarodna recenzija, pregledni rad, znanstveni)
CROSBI ID: 1248222 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Silicon foil patching for blast tympanic membrane
perforation: a retrospective study
Autori
Branica, Srećko ; Dawidowsky, Krsto ; Kovač Bilić, Lana ; Bilić, Mario
Izvornik
Croatian medical journal (0353-9504) 60
(2019), 6;
503-507
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, pregledni rad, znanstveni
Ključne riječi
tympanic membrane ; perforation ; silicon
Sažetak
Aim To establish whether covering the tympanic membrane perforation after war blast injury with silicon foil can enhance the ear drum healing rate and to determine the appropriate timing of silicon patching. Methods We retrospectively analyzed the charts of 210 patients wounded during the Homeland War in Croatia 1991-1995, with 315 blast tympanic membrane perforations. In 44 patients (61 perforations), the eardrum perforation was covered by silicon foil, whereas in 166 patients (254 perforations) it was left to heal spontaneously. The patients who underwent the patching procedure were divided in two groups according to the time period between the blast injury and the procedure: 38 perforations were treated within 3 days and 23 perforations were treated 4 to 6 days after the blast injury. Results The rate of tympanic membrane healing in the silicon foil patching group was significantly higher (91.8%) than that in the group of perforations left to heal spontaneously (79.9%, P = 0.029). The healing rate was significantly higher in the group treated within 3 days after the blast injury (97.4%) than in the group treated 4 to 6 days after the injury (82.6%, P = 0.042). Conclusion Covering the perforation after the war blast injury with silicon foil significantly improves the rate of tympanic membrane healing. To obtain the best healing outcome, the procedure should be performed within the first 72 hours after the trauma.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE