Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1247366

Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes


Bencic, G; Vatavuk, Z; Marotti, M; Loncar, V L; Petric, I; Andrijevic-Derk, B; Skunca, J; Mandic, Z
Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes // British Journal of Ophthalmology, 93 (2008), 4; 502-505 doi:10.1136/bjo.2008.147868 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1247366 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes

Autori
Bencic, G ; Vatavuk, Z ; Marotti, M ; Loncar, V L ; Petric, I ; Andrijevic-Derk, B ; Skunca, J ; Mandic, Z

Izvornik
British Journal of Ophthalmology (0007-1161) 93 (2008), 4; 502-505

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
axial length ; silicone oil filled eye ; A scan ; MRI

Sažetak
Aims: The aim of the study was to compare the accuracy of A-scan biometry and MRI for the measurement of axial length in silicone oil-filled eyes. Methods: This was a prospective randomised study of 70 patients. Biometry was performed using MRI in 33 patients (MRI group) and A-scan echography in 37 patients (A-scan group). The difference between predicted and final refraction was measured and evaluated statistically. Results: In patients with axial length ⩾26 mm, the mean deviation of the final from predicted refraction was −1.23 (SD 0.67) D in the MRI group and −2.3 (SD 2.02) D in the A- scan group. The difference between these two groups was statistically significant (p = 0.02). In patients with axial length <26 mm, the mean deviation of the final from predicted refraction was −0.12 (SD 1.29) D in the MRI group and −0.33 (SD 1.39) D in the A-scan group. There was no statistical significance between the two groups (p = 0.629). Conclusion: For highly myopic patients MRI biometry was a more accurate measurement of axial length in silicone oil-filled eyes. A-scan and MRI biometry were comparably accurate in measuring axial length in patients with axial length <26 mm.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti

Poveznice na cjeloviti tekst rada:

doi

Poveznice na istraživačke podatke:

bjo.bmj.com

Citiraj ovu publikaciju:

Bencic, G; Vatavuk, Z; Marotti, M; Loncar, V L; Petric, I; Andrijevic-Derk, B; Skunca, J; Mandic, Z
Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes // British Journal of Ophthalmology, 93 (2008), 4; 502-505 doi:10.1136/bjo.2008.147868 (međunarodna recenzija, članak, znanstveni)
Bencic, G., Vatavuk, Z., Marotti, M., Loncar, V., Petric, I., Andrijevic-Derk, B., Skunca, J. & Mandic, Z. (2008) Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes. British Journal of Ophthalmology, 93 (4), 502-505 doi:10.1136/bjo.2008.147868.
@article{article, author = {Bencic, G and Vatavuk, Z and Marotti, M and Loncar, V L and Petric, I and Andrijevic-Derk, B and Skunca, J and Mandic, Z}, year = {2008}, pages = {502-505}, DOI = {10.1136/bjo.2008.147868}, keywords = {axial length, silicone oil filled eye, A scan, MRI}, journal = {British Journal of Ophthalmology}, doi = {10.1136/bjo.2008.147868}, volume = {93}, number = {4}, issn = {0007-1161}, title = {Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes}, keyword = {axial length, silicone oil filled eye, A scan, MRI} }
@article{article, author = {Bencic, G and Vatavuk, Z and Marotti, M and Loncar, V L and Petric, I and Andrijevic-Derk, B and Skunca, J and Mandic, Z}, year = {2008}, pages = {502-505}, DOI = {10.1136/bjo.2008.147868}, keywords = {axial length, silicone oil filled eye, A scan, MRI}, journal = {British Journal of Ophthalmology}, doi = {10.1136/bjo.2008.147868}, volume = {93}, number = {4}, issn = {0007-1161}, title = {Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes}, keyword = {axial length, silicone oil filled eye, A scan, MRI} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font