Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1246534

THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW”


Novosel, Dragutin; Žuljević, P; Alanović, M; Zunac, Robert; Bečić, Tina
THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW” // Paripex Indian journal of research, 11 (2022), 11; 55-60 doi:10.36106/paripex/4505716 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1246534 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW”

Autori
Novosel, Dragutin ; Žuljević, P ; Alanović, M ; Zunac, Robert ; Bečić, Tina

Izvornik
Paripex Indian journal of research (2250-1991) 11 (2022), 11; 55-60

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
electrocardiogram ; limb leads ; magnitude ; resistance ; heart axis ; Novosel formula ; Monte-Carlo Simulation ; Ohm's law

Sažetak
Our paper analyses the interdependence between the overall magnitudes and resistances of bipolar and augmented unipolar limb leads of electrocardiograms.The findings strongly indicate that the overall ratio of magnitude of the bipolar and augmented unipolar limb leads is not a constant value, whereas the overall ratio of resistance is a constant value.These results expand but partially contradict a previous study. The ratio of the magnitude of bipolar leads to augmented unipolar leads is between 1 and 4/3 with a mean value of 2/√3, and this ratio is a function of the electrical axis of the heart.Our results also show that the overall ratio of resistance between bipolar and augmented unipolar limb leads approaches the value of 4/3. Conclusively, the ratio of magnitudes between limb leads is not a constant value, the ratio of resistances can be assumed as a constant value and therefore the difference of magnitudes between limb leads cannot be explained with the Ohm's law.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
KBC Split,
Medicinski fakultet, Split

Profili:

Avatar Url Dragutin Novosel (autor)

Avatar Url Robert Žunac (autor)

Avatar Url Tina Bečić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Novosel, Dragutin; Žuljević, P; Alanović, M; Zunac, Robert; Bečić, Tina
THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW” // Paripex Indian journal of research, 11 (2022), 11; 55-60 doi:10.36106/paripex/4505716 (međunarodna recenzija, članak, znanstveni)
Novosel, D., Žuljević, P., Alanović, M., Zunac, R. & Bečić, T. (2022) THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW”. Paripex Indian journal of research, 11 (11), 55-60 doi:10.36106/paripex/4505716.
@article{article, author = {Novosel, Dragutin and \v{Z}uljevi\'{c}, P and Alanovi\'{c}, M and Zunac, Robert and Be\v{c}i\'{c}, Tina}, year = {2022}, pages = {55-60}, DOI = {10.36106/paripex/4505716}, keywords = {electrocardiogram, limb leads, magnitude, resistance, heart axis, Novosel formula, Monte-Carlo Simulation, Ohm's law}, journal = {Paripex Indian journal of research}, doi = {10.36106/paripex/4505716}, volume = {11}, number = {11}, issn = {2250-1991}, title = {THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW”}, keyword = {electrocardiogram, limb leads, magnitude, resistance, heart axis, Novosel formula, Monte-Carlo Simulation, Ohm's law} }
@article{article, author = {Novosel, Dragutin and \v{Z}uljevi\'{c}, P and Alanovi\'{c}, M and Zunac, Robert and Be\v{c}i\'{c}, Tina}, year = {2022}, pages = {55-60}, DOI = {10.36106/paripex/4505716}, keywords = {electrocardiogram, limb leads, magnitude, resistance, heart axis, Novosel formula, Monte-Carlo Simulation, Ohm's law}, journal = {Paripex Indian journal of research}, doi = {10.36106/paripex/4505716}, volume = {11}, number = {11}, issn = {2250-1991}, title = {THE CHALLENGES AND PITFALLS OF LIMB-LEADS AND HEART-AXIS CALCULATIONS “THE DIFFERENCES BETWEEN THE OVERALL MAGNITUDES OF BIPOLAR AND AUGMENTED UNIPOLAR LEADS CANNOT BE EXPLAINED WITH THE OHM'S LAW”}, keyword = {electrocardiogram, limb leads, magnitude, resistance, heart axis, Novosel formula, Monte-Carlo Simulation, Ohm's law} }

Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font