Pregled bibliografske jedinice broj: 1241774
Dose Rate Assessment Around The PCFV Release Line During Severe Accident Conditions in Nuclear Power Plant Krsko
Dose Rate Assessment Around The PCFV Release Line During Severe Accident Conditions in Nuclear Power Plant Krsko // NENE 2022 Conference Proceedings / Jenčič, Igor (ur.).
Ljubljana: Nuclear Society of Slovenia, 2022. str. 1-11 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1241774 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Dose Rate Assessment Around The PCFV Release Line
During Severe Accident Conditions in Nuclear Power
Plant Krsko
Autori
Grgić, Davor ; Dučkić, Paulina ; Benčik, Vesna ; Šadek, Siniša
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
NENE 2022 Conference Proceedings
/ Jenčič, Igor - Ljubljana : Nuclear Society of Slovenia, 2022, 1-11
ISBN
978-961-6207-53-9
Skup
31st International Conference Nuclear Energy for New Europe brought together (NENE2022)
Mjesto i datum
Portorož, Slovenija, 12.09.2022. - 15.09.2022
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
dose rate, PCFV, severe accident, station blackout, MELCOR, MCNP
Sažetak
Passive Containment Filtered Vent (PCFV) was installed in Nuclear Power Plant (NPP) Krško in 2013 as a part of safety upgrade program. It is intended for severe accident consequences prevention and mitigation by ensuring the containment integrity. When the pressure in the containment reaches limiting value, the containment atmosphere is released in the environment through the PCFV system exhaust line. But, before release in the environment, the containment atmosphere passes through five aerosol filters in containment and an iodine filter in the auxiliary building to reduce isotopic activity. In this paper, dose rates around the exhaust line of the PCFV system resulting from radioactivity release in case of a severe accident are determined. The assumed severe accident scenario is a beyond design basis station blackout (SBO) in NPP Krško, which is simulated by using the MELCOR code. Its results are input for the radiological calculations to obtain the activities released in the containment. The obtained activities are then transformed into the gamma source intensity and spectrum using the ORIGEN-S libraries. This form of the source term is required for the Monte Carlo calculations. The source is present in the containment and in the PCFV duct. The dose rates around the duct are calculated using MCNP6.2 code.