Pregled bibliografske jedinice broj: 1231280
OPTIMIZATION OF LC-QqQ-MS/MS METHOD FOR QUANTIFICATION OF ANDROGRAPHOLIDES IN HUMAN PLASMA
OPTIMIZATION OF LC-QqQ-MS/MS METHOD FOR QUANTIFICATION OF ANDROGRAPHOLIDES IN HUMAN PLASMA // SOLUTIONS IN CHEMISTRY / Kassal, Petar ; Meštrović, Ernest ; Namjesnik, Danijel ; Ribić, Rosana ; Šekutor, Marina ; Tomišić, Vladislav, Usenik, Andrea (ur.).
Zagreb: Hrvatsko kemijsko društvo, 2022. str. 98-98 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 1231280 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
OPTIMIZATION OF LC-QqQ-MS/MS METHOD FOR
QUANTIFICATION OF ANDROGRAPHOLIDES IN HUMAN PLASMA
Autori
Kovačić, Jelena ; Jeličić, Mario-Livio ; Amidžić Klarić, Daniela ; Mornar, Ana
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
SOLUTIONS IN CHEMISTRY
/ Kassal, Petar ; Meštrović, Ernest ; Namjesnik, Danijel ; Ribić, Rosana ; Šekutor, Marina ; Tomišić, Vladislav, Usenik, Andrea - Zagreb : Hrvatsko kemijsko društvo, 2022, 98-98
ISBN
978-953-8334-05-4
Skup
International Conference Solutions in Chemistry 2022
Mjesto i datum
Sveti Martin na Muri, Hrvatska, 08.11.2022. - 11.11.2002
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
IBD ; LC-QqQ-MS/MS ; human plasma, andrographolides
Sažetak
Andrographolides are diterpenoids found in the plant Andrographis paniculata and are widely used in traditional medicine, exhibiting anti- inflammatory properties.1 In this research we developed and validated high-performance liquid chromatography coupled with electrospray ionization triple-quadrupole tandem mass spectrometry (LC-QqQ-MS/MS) method for quantification of andrographolides in human plasma. The chromatographic analysis of pharmacological active andrographolide (AND), neoandrographolide (NAND) and 14-deoxy11, 12- didehydroandrographolide (DAND) was performed on a 15 cm HSS Cyano column with a gradient mobile phase of ultra-pure water and acetonitrile with the addition of formic acid (0.1%) as a modifier at a flow rate of 0.8 mL/min in 21 min. The validation results showed acceptable linearity of the method (r>0.999) for all analytes within the calibration range 0.7–10 µg/mL. The acceptable accuracy of the method was indicated by recovery of 90–107 %. The limit of quantification was found to be between 2 and 70 ng/mL while the limit of detection was found between 0.6 and 20 ng/mL. Multiple reaction monitoring (MRM) mode was optimized to quantify data under monitoring precursor-product ion transitions of m/z 351.1 → 105.0, 351.5 → 91.0, 351.1 → 79.0 and 351.1 → 77.0 for AND, m/z 481.6 319.0, 481.6 301.2, 481.6 289.2, 481.6 95.1 for NAND and m/z 333.1 314.9, 333.1 297.2, 333.1 257.3, 333.1 91.0 for DAND (Figure 1). This advanced method is simple, selective, accurate and cost-effective. As a result, this assay can be easily transferred in clinical settings for pharmacokinetic studies and therapeutic drug monitoring programs. ACKNOWLEDGEMENTS This work has been supported in part by the Croatian Science Foundation under the project numbers [UIP-2017-05-3949, DOK-2021- 02-7922] and project FarmInova (KK.01.1.1.02.0021) funded by the European Regional Development Fund.
Izvorni jezik
Engleski
Znanstvena područja
Farmacija
POVEZANOST RADA
Projekti:
UIP-2017-05-3949 - Razvoj naprednih analitičkih metoda za lijekove i biološki aktivne tvari u liječenju upalnih bolesti crijeva (IBDAnalytics) (Mornar Turk, Ana, HRZZ - 2017-05) ( CroRIS)
EK-EFRR-KK.01.1.1.02.0021 - Jačanje znanstveno-istraživačkih i inovacijskih kapaciteta Farmaceutsko-biokemijskog fakulteta Sveučilišta u Zagrebu (FarmInova) (Lovrić, Jasmina, EK - Ulaganje u organizacijsku reformu i infrastrukturu u sektoru istraživanja, razvoja i inovacija) ( CroRIS)
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb
Profili:
Ana Mornar Turk
(autor)
Daniela Amidžić Klarić
(autor)
Mario-Livio Jeličić
(autor)
Jelena Kovačić
(autor)