Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1229941

Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness


Hu, Zhenwei; Sun, Jie; Wang, Jin; Ma, Ting; Baleta, Jakov; Sundén, Bengt
Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness // Fuel, 323 (2022), 124434, 10 doi:10.1016/j.fuel.2022.124434 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1229941 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness

Autori
Hu, Zhenwei ; Sun, Jie ; Wang, Jin ; Ma, Ting ; Baleta, Jakov ; Sundén, Bengt

Izvornik
Fuel (0016-2361) 323 (2022); 124434, 10

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Applied voltage ; Combustor ; Gas turbine ; Plasma actuator ; Swirler blade angle ; Temperature field

Sažetak
This paper investigated effects of swirlers with blade angles and applied voltage of plasma actuators on combustion and wall temperature of a Can - type gas turbine combustor. Results show that large blade angle of the swirler is beneficial for the mixing of fuel and air, which improves uniformity of the outlet temperature distribution and reduces CO emission but results in temperature rise of the wall. Pattern factor reflects uniformity of the temperature distribution at the outlet of the combustion chamber, and a small value of the pattern factor means a good distribution uniformity. In this paper, the minimum pattern factor is 0.45 when the blade angle of the swirler is 55◦, which means the best uniformity of temperature distribution at combustor outlet. Compared with the worst results with a 40◦ blade angle, the pattern factor for the blade angle of 55◦ decreases by 66.4%. CO emission decreases with the increase of the blade angle. Compared with the maximum value of CO emission for a 40◦ blade angle, reductions of CO emission are 67.6%, 95.9% and 99.6% with the blade angles of 45◦, 50◦ and 55◦. It is found that CO emission decreases by 1.3% and pattern factor increases by 2.2%, when the blade angle of the swirler changes from 55◦ to 60◦. When the applied voltage changes from 0 kV to 8 kV and 16 kV, cooling effectiveness increases by 3.2% and 0.7%. Cooling effectiveness decreases by 2.9% when the applied voltage increases from 0 kV to 24 kV.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Metalurški fakultet, Sisak

Profili:

Avatar Url Jakov Baleta (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Hu, Zhenwei; Sun, Jie; Wang, Jin; Ma, Ting; Baleta, Jakov; Sundén, Bengt
Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness // Fuel, 323 (2022), 124434, 10 doi:10.1016/j.fuel.2022.124434 (međunarodna recenzija, članak, znanstveni)
Hu, Z., Sun, J., Wang, J., Ma, T., Baleta, J. & Sundén, B. (2022) Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness. Fuel, 323, 124434, 10 doi:10.1016/j.fuel.2022.124434.
@article{article, author = {Hu, Zhenwei and Sun, Jie and Wang, Jin and Ma, Ting and Baleta, Jakov and Sund\'{e}n, Bengt}, year = {2022}, pages = {10}, DOI = {10.1016/j.fuel.2022.124434}, chapter = {124434}, keywords = {Applied voltage, Combustor, Gas turbine, Plasma actuator, Swirler blade angle, Temperature field}, journal = {Fuel}, doi = {10.1016/j.fuel.2022.124434}, volume = {323}, issn = {0016-2361}, title = {Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness}, keyword = {Applied voltage, Combustor, Gas turbine, Plasma actuator, Swirler blade angle, Temperature field}, chapternumber = {124434} }
@article{article, author = {Hu, Zhenwei and Sun, Jie and Wang, Jin and Ma, Ting and Baleta, Jakov and Sund\'{e}n, Bengt}, year = {2022}, pages = {10}, DOI = {10.1016/j.fuel.2022.124434}, chapter = {124434}, keywords = {Applied voltage, Combustor, Gas turbine, Plasma actuator, Swirler blade angle, Temperature field}, journal = {Fuel}, doi = {10.1016/j.fuel.2022.124434}, volume = {323}, issn = {0016-2361}, title = {Effects of swirler blade angle and actuator applied voltage on combustion characteristics and cooling effectiveness}, keyword = {Applied voltage, Combustor, Gas turbine, Plasma actuator, Swirler blade angle, Temperature field}, chapternumber = {124434} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font