Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1229322

Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients


Kovacic, Vedran; Roguljic, Luka; Kovacic, Vinko; Bacic, Boris; Bosnjak, Tamara
Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients // Renal Failure, 25 (2003), 6; 945-951 doi:10.1081/jdi-120026029 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1229322 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients

Autori
Kovacic, Vedran ; Roguljic, Luka ; Kovacic, Vinko ; Bacic, Boris ; Bosnjak, Tamara

Izvornik
Renal Failure (0886-022X) 25 (2003), 6; 945-951

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Ultrafiltration ; Blood pressure ; Hemodialysis

Sažetak
Introduction: Volume overload is a main factor in development of hypertension in hemodialysis patients. In order to demonstrate impact of ultrafiltration volume on blood pressure during 15-months period in a group of patients undergoing chronic hemodialysis therapy, we conducted this study. We hypothesized that ultrafiltration volume different affects the pre/postdialysis systolic pressure, diastolic pressure, mean arterial pressure (MAP), and pulse pressure (PP) values. Subjects and methods: Study subjects were 23 anuric chronically hemodialyzed patients. The overall study time was 15 months, and 136 single hemodialysis treatments were analyzed. Results: Ultrafiltration was negatively correlated with predialysis systolic blood pressure (r = -0.169, p = 0.025), postdialysis systolic blood pressure (r = -0.292, p < 0.001), postdialysis MAP (r = -0.186, p = 0.015), predialysis PP (r = -0.290, p < 0.001), and postdialysis PP (r = -0.370, p < 0.001). Ultrafiltration/dry body mass (UF/W) ratio was negatively correlated with predialysis PP (r = -0.222, p = 0.005), postdialysis PP (r = -0.340, p < 0.001), and postdialysis systolic blood pressure (r = -0.243, p = 0.002). We found significant difference in postdialysis PP between dialyses with UF/W ratio < or = 0.05 an dialyses with UF/W ratio > 0.05 (63.49 +/- 20.76 vs. 56.27 +/- 16.33 mmHg, p = 0.033). Conclusion: The ultrafiltration volume strongly affects postdialysis PP values. Evaluation of elevated blood pressure treatment in patients undergoing chronic hemodialysis therapy must be considered in respect of postdialysis PP values, not just depending on pre/postdialysis systolic and diastolic pressur or MAP values.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Split

Profili:

Avatar Url Boris Bačić (autor)

Avatar Url Vinko Kovačić (autor)

Avatar Url Vedran Kovačić (autor)

Poveznice na cjeloviti tekst rada:

doi www.tandfonline.com

Citiraj ovu publikaciju:

Kovacic, Vedran; Roguljic, Luka; Kovacic, Vinko; Bacic, Boris; Bosnjak, Tamara
Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients // Renal Failure, 25 (2003), 6; 945-951 doi:10.1081/jdi-120026029 (međunarodna recenzija, članak, znanstveni)
Kovacic, V., Roguljic, L., Kovacic, V., Bacic, B. & Bosnjak, T. (2003) Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients. Renal Failure, 25 (6), 945-951 doi:10.1081/jdi-120026029.
@article{article, author = {Kovacic, Vedran and Roguljic, Luka and Kovacic, Vinko and Bacic, Boris and Bosnjak, Tamara}, year = {2003}, pages = {945-951}, DOI = {10.1081/jdi-120026029}, keywords = {Ultrafiltration, Blood pressure, Hemodialysis}, journal = {Renal Failure}, doi = {10.1081/jdi-120026029}, volume = {25}, number = {6}, issn = {0886-022X}, title = {Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients}, keyword = {Ultrafiltration, Blood pressure, Hemodialysis} }
@article{article, author = {Kovacic, Vedran and Roguljic, Luka and Kovacic, Vinko and Bacic, Boris and Bosnjak, Tamara}, year = {2003}, pages = {945-951}, DOI = {10.1081/jdi-120026029}, keywords = {Ultrafiltration, Blood pressure, Hemodialysis}, journal = {Renal Failure}, doi = {10.1081/jdi-120026029}, volume = {25}, number = {6}, issn = {0886-022X}, title = {Ultrafiltration Volume Is Associated with Changes in Blood Pressure in Chronically Hemodialyzed Patients}, keyword = {Ultrafiltration, Blood pressure, Hemodialysis} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font