Pregled bibliografske jedinice broj: 122687
Utjecaj kvalitete kontakta između apsorbera i cijevi na efikasnost pločastog sunčevog kolektora
Utjecaj kvalitete kontakta između apsorbera i cijevi na efikasnost pločastog sunčevog kolektora // Energy and the Environment, Vol. II / Franković, Bernard (ur.).
Opatija: Hrvatski savez za sunčevu energiju, 2002. str. 273-280 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 122687 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Utjecaj kvalitete kontakta između apsorbera i cijevi na efikasnost pločastog sunčevog kolektora
(Influence of the goodness of apsorber and tube contact on flat plate solar collector efficiency)
Autori
Suša, Mirela ; Tomek, Goran ; Dović, Damir ; Švaić, Srećko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Energy and the Environment, Vol. II
/ Franković, Bernard - Opatija : Hrvatski savez za sunčevu energiju, 2002, 273-280
Skup
18. znanstveni skup o energiji i zaštiti okoliša
Mjesto i datum
Opatija, Hrvatska, 23.10.2002. - 25.10.2002
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
kolektori sunčevog zračenja; mjerenja; apsorber kolektora; efikasnost
(solar collectors; mesurements; collector absorber; efficiency)
Sažetak
This work analyses the influence of the contact between absorber and tube on the flat plate type solar collector efficiency. The analysis is performed experimentally and computationally by varying the overall heat transfer coefficient kkontakt defined for the heat flow from absorber to water flowing in tube. First part of the paper provides the test data for two collectors of the same construction but having different number of the brazed joints between absorber and tube. Better contact yields 20% increase in the efficiency. Based on the measurements the overall heat transfer coefficient kkontakt is computed for both tested collectors in order to investigate a possible further increase in the collector efficiency with higher values of contact i.e. having additionally improved contact between absorber and tube The results indicate noticeable increase in the collector efficiency with kkontakt - up to 30% when compared to the test results for the collector with the worse contact.
Izvorni jezik
Hrvatski
Znanstvena područja
Strojarstvo