Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1224917

Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object


Mihanović, Frane; Ivanović, Anita
Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object // St open, 1 (2020), 1-11 doi:10.48188/so.1.1 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1224917 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object

Autori
Mihanović, Frane ; Ivanović, Anita

Izvornik
St open (2718-3734) 1 (2020); 1-11

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
panoramic radiograph, dentoalveolar anatomy, Cone-beam computed tomography, image distortion, PEG and DICOM image format, posterior mandibular implants

Sažetak
Aim: To investigate the accuracy of measurements in vertical and horizontal direction using an extra-oral calibration object placed in different positions on the panoramic radiograph in JPEG and DICOM image format. Methods: Digital panoramic radiographs of a purpose made model with 32 removable teeth replaced with metal balls were taken. The measurements of metal balls were performed with and without the calibration object placed in the middle or on the side of the radiograph in JPEG and DICOM image formats. Results: One sample t-test was used for the analyses of accuracy of measurements in vertical and horizontal direction. The most accurate vertical measurements were achieved in canine group in JPEG (6.02±0.04 mm, P=0.144) and DICOM (6.03±0.07 mm, P=0.104) formats using calibration object placed in the middle of the radiograph. The mean values of measurements in horizontal direction differed significantly from the real values (P<0.05) in all teeth groups regardless of the image format. Conclusion: The most accurate measurements in vertical direction were achieved by placing the metal scale ruler extra-orally in the middle of panoramic radiograph independent of the image format. Reliable clinical accuracy for measurements in horizontal direction was achieved only in canine region (G2) in both image formats

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Ustanove:
Sveučilište u Splitu Sveučilišni odjel zdravstvenih studija

Profili:

Avatar Url Frane Mihanović (autor)

Poveznice na cjeloviti tekst rada:

doi st-open.unist.hr

Citiraj ovu publikaciju:

Mihanović, Frane; Ivanović, Anita
Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object // St open, 1 (2020), 1-11 doi:10.48188/so.1.1 (međunarodna recenzija, članak, znanstveni)
Mihanović, F. & Ivanović, A. (2020) Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object. St open, 1, 1-11 doi:10.48188/so.1.1.
@article{article, author = {Mihanovi\'{c}, Frane and Ivanovi\'{c}, Anita}, year = {2020}, pages = {1-11}, DOI = {10.48188/so.1.1}, keywords = {panoramic radiograph, dentoalveolar anatomy, Cone-beam computed tomography, image distortion, PEG and DICOM image format, posterior mandibular implants}, journal = {St open}, doi = {10.48188/so.1.1}, volume = {1}, issn = {2718-3734}, title = {Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object}, keyword = {panoramic radiograph, dentoalveolar anatomy, Cone-beam computed tomography, image distortion, PEG and DICOM image format, posterior mandibular implants} }
@article{article, author = {Mihanovi\'{c}, Frane and Ivanovi\'{c}, Anita}, year = {2020}, pages = {1-11}, DOI = {10.48188/so.1.1}, keywords = {panoramic radiograph, dentoalveolar anatomy, Cone-beam computed tomography, image distortion, PEG and DICOM image format, posterior mandibular implants}, journal = {St open}, doi = {10.48188/so.1.1}, volume = {1}, issn = {2718-3734}, title = {Accuracy of measurements performed on digital panoramic radiographs with and without an extra- oral calibration object}, keyword = {panoramic radiograph, dentoalveolar anatomy, Cone-beam computed tomography, image distortion, PEG and DICOM image format, posterior mandibular implants} }