Pregled bibliografske jedinice broj: 1222889
Functionalization of cotton/polyester fabric with dimethyltetradecyl (3-(trimethoxysyl) ammonium chloride
Functionalization of cotton/polyester fabric with dimethyltetradecyl (3-(trimethoxysyl) ammonium chloride // Book of Proceedings of the 10th International textile, clothing & design conference - Magic world of textiles / Dragčević, Zvonko ; Hursa Šajatović, Anica ; Vujasinović, Edita (ur.).
Zagreb: Tekstilno-tehnološki fakultet Sveučilišta u Zagrebu, 2022. str. 136-141 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1222889 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Functionalization of cotton/polyester fabric with
dimethyltetradecyl (3-(trimethoxysyl) ammonium
chloride
Autori
Palčić, Ana ; Flinčec Grgac, Sandra ; Vasiljević, Ana ; Tarbuk, Anita
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Book of Proceedings of the 10th International textile, clothing & design conference - Magic world of textiles
/ Dragčević, Zvonko ; Hursa Šajatović, Anica ; Vujasinović, Edita - Zagreb : Tekstilno-tehnološki fakultet Sveučilišta u Zagrebu, 2022, 136-141
Skup
10th International Textile, Clothing & Design Conference: Magic world of textiles
Mjesto i datum
Dubrovnik, Hrvatska, 02.10.2022. - 05.10.2022
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
dimethyltetradecyl (3-(trimethoxysilyl) ammonium chloride ; cotton/polyester ; FTIR-ATR ; electrokinetic analyzer ; antimicrobial activity
Sažetak
In this study, the antimicrobial ability of textile fabrics achieved with dimethyltetradecyl (3-(trimethoxysilyl) ammonium chloride in the presence of 1, 2, 3, 4-butane tetracarboxylic acid was investigated. A conventional dip-pad-dry-cure method was applied for antimicrobial textile finishing. After dipping samples were aged in the bath for 24 h and then padded on a padding machine, dried for 2 min at 110 °C and then thermocondensed at 160 °C for 5 min. Samples were washed according to the standard EN ISO 15797 up to 3 washing cycles. Physicochemical changes on the treated fabrics before and after washing were tested by Fourier infrared spectrometry in ATR technique (FTIR-ATR), and the electrokinetic analyse was performed to determine change in the fabric surface charge on SurPASS. The antimicrobial activity of the fabrics was determined according to the AATCC 147 standard. The pH values of the material surface after one and three washing cycles were also determined.
Izvorni jezik
Engleski
Znanstvena područja
Tekstilna tehnologija
POVEZANOST RADA
Projekti:
HRZZ-UIP-2017-05-8780 - Bolničke zaštitne tekstilije (HPROTEX) (Flinčec Grgac, Sandra, HRZZ - UIP-2017-05) ( CroRIS)
Ustanove:
Tekstilno-tehnološki fakultet, Zagreb,
Nastavni zavod za javno zdravstvo "Dr. Andrija Štampar"