Pregled bibliografske jedinice broj: 1219831
Calibration and Verification of Operation Parameters for an Array of Vectrino Profilers Configured for Turbulent Flow Field Measurement around Bridge Piers—Part I
Calibration and Verification of Operation Parameters for an Array of Vectrino Profilers Configured for Turbulent Flow Field Measurement around Bridge Piers—Part I // Fluids, 7 (2022), 10; 315, 18 doi:10.3390/fluids7100315 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1219831 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Calibration and Verification of Operation
Parameters for an Array of Vectrino Profilers
Configured for Turbulent Flow Field Measurement
around Bridge Piers—Part I
Autori
Gilja, Gordon ; Fliszar, Robert ; Harasti, Antonija ; Valyrakis, Manousos
Izvornik
Fluids (2311-5521) 7
(2022), 10;
315, 18
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
acoustic doppler velocimeter ; Vectrino Profiler operation parameters ; Acoustic Doppler Current Profiler ; bridge scour ; turbulence ; hydraulic flume
Sažetak
Flow mapping around bridge piers is crucial in estimating scour development potential under different flow conditions. The reliable measurement of turbulence and the estimation of Reynolds stress can be achieved on scaled models under controlled laboratory experiments using high-frequency Acoustic Doppler Velocimeter Profilers (ADVP) for flow measurement. The aim of this paper was to obtain operation parameters for an array of Vectrino Profilers for turbulent flow field measurement to reliably measure the flow field around bridge piers. Laboratory experiments were conducted on a scaled river model set up in an open channel hydraulic flume. Flow field data were measured on three characteristic profiles, each containing five measurement points collected by ADVPs configured as an array of two instruments. The determination of the operation parameters was done as a two-step process— calibration through the flume’s pump flow rate and verification with Acoustic Doppler Current Profiler RioGrande field data. Based on the results, the following setup for ADVPs’ operation parameters can be used to obtain reliable flow data in the scour hole next to the bridge pier: adaptive Ping Algorithm, Transmit Pulse Size of 4 mm and Cell Size of 1 mm.
Izvorni jezik
Engleski
Znanstvena područja
Geofizika, Građevinarstvo, Interdisciplinarne tehničke znanosti
POVEZANOST RADA
Projekti:
UIP-2019-04-4046 - Daljinsko praćenje erozije riprap zaštite od podlokavanja na velikim rijekama u stvarnom vremenu (R3PEAT) (Gilja, Gordon, HRZZ - 2019-04) ( CroRIS)
Ustanove:
Građevinski fakultet, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Emerging Sources Citation Index (ESCI)
- Scopus
Uključenost u ostale bibliografske baze podataka::
- INSPEC