Earthing effects of bare conductor laid alongside underground power cables


Medić, Ivan; Sarajčev, Ivan; Majstrović, Matislav
Earthing effects of bare conductor laid alongside underground power cables // Proceedings of the Second IASTED International Conference Power and energy systems / Contaxis, George ; Antonidakis, Manolis (ur.).
Anaheim : Calgary : Zurich: ACTA Press, 2002. str. 612-616 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 121583 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Earthing effects of bare conductor laid alongside underground power cables

Autori
Medić, Ivan ; Sarajčev, Ivan ; Majstrović, Matislav

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the Second IASTED International Conference Power and energy systems / Contaxis, George ; Antonidakis, Manolis - Anaheim : Calgary : Zurich : ACTA Press, 2002, 612-616

Skup
Power and energy systems

Mjesto i datum
Kreta, Grčka, 25.06.2002. - 28.06.2002

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
grounding; cable sheath; inductive coupling; earthing wire

Sažetak
An analytical method is presented to determine the line-to-ground fault current distribution and related voltages in the earthing system which consists of two substation earthings interconected by insulated metal sheaths of modern XLPE cables and one bare earthing wire laid in parallel in the same cable trench. The equations derived are based on the assumption of uniformly distributed conductance between the earthing wire and earth. The proposed method takes into account inductive coupling between cable sheaths and the earthing wire. The effects of connecting bare earthing wire parallel to insulated cable sheaths as well as that of their mutual inductance, are outlined. These effects may have significant influence on current and voltage distribution in earthing system. It is assumed that power cables operate in the network with non-directly earthed neutral point (e.g. 10-35 kV) so that relevant zero-sequence current is coming from another, directly earthed high voltage (h.v.) network.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0023015
0201001

Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split

Profili:

Avatar Url Ivan Sarajčev (autor)

Avatar Url Matislav Majstrović (autor)

Avatar Url Ivan Medić (autor)


Citiraj ovu publikaciju:

Medić, Ivan; Sarajčev, Ivan; Majstrović, Matislav
Earthing effects of bare conductor laid alongside underground power cables // Proceedings of the Second IASTED International Conference Power and energy systems / Contaxis, George ; Antonidakis, Manolis (ur.).
Anaheim : Calgary : Zurich: ACTA Press, 2002. str. 612-616 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Medić, I., Sarajčev, I. & Majstrović, M. (2002) Earthing effects of bare conductor laid alongside underground power cables. U: Contaxis, G. & Antonidakis, M. (ur.)Proceedings of the Second IASTED International Conference Power and energy systems.
@article{article, author = {Medi\'{c}, Ivan and Saraj\v{c}ev, Ivan and Majstrovi\'{c}, Matislav}, year = {2002}, pages = {612-616}, keywords = {grounding, cable sheath, inductive coupling, earthing wire}, title = {Earthing effects of bare conductor laid alongside underground power cables}, keyword = {grounding, cable sheath, inductive coupling, earthing wire}, publisher = {ACTA Press}, publisherplace = {Kreta, Gr\v{c}ka} }
@article{article, author = {Medi\'{c}, Ivan and Saraj\v{c}ev, Ivan and Majstrovi\'{c}, Matislav}, year = {2002}, pages = {612-616}, keywords = {grounding, cable sheath, inductive coupling, earthing wire}, title = {Earthing effects of bare conductor laid alongside underground power cables}, keyword = {grounding, cable sheath, inductive coupling, earthing wire}, publisher = {ACTA Press}, publisherplace = {Kreta, Gr\v{c}ka} }




Contrast
Increase Font
Decrease Font
Dyslexic Font