Determination of the Best Air Space Value for Installation of a PV Façade Technology Based on 4E Characteristics
Determination of the Best Air Space Value for Installation of a PV Façade Technology Based on 4E Characteristics // Energy (Oxford), 262 (2023), 125386, 15 doi:10.1016/j.energy.2022.125386 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1212339 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Determination of the Best Air Space Value for
Installation of a PV Façade Technology Based on 4E
Characteristics
Autori
Ali, Sohani ; Hoseyn, Sayyaadi ; Seyed Rahman, Miremadi ; Xiaohu, Yang ; Mohammad, Hossein Doranehgard ; Sandro, Nižetić
Izvornik
Energy (Oxford) (0360-5442) 262
(2023);
125386, 15
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
4E characteristics ; Building performance simulation ; PV façade technology ; Optimal air space ; Renewable energy
Sažetak
Impact of changing the air gap, as the main geometrical characteristic of a PV façade (BIPV/T) system, is investigated to find the optimal value. It is done by considering annual CO2 emission reduction and annual useful exergy from the environmental and exergy sides, while annual electricity production and annual recovered heat are also investigated as representatives of energy aspect. In addition to the mentioned performance criteria, three key economic indicators, namely the overall fund saving, levelized cost of electricity, and payback time, are investigated, which results in conducting a comprehensive energy, exergy, environmental, and economic (4E) analysis. The conducted 4E analysis demonstrates that BIPV/T performance is heavily dependent on the air gap. Based on the results, for the investigated building, located in Tehran, Iran, 5.45, 5.68, 19.89, and 37.86% changes in the total fund saving, annual useful exergy, annual CO2 emission reduction, and annual heat recovered are seen when air gap varies from 0.05 to 0.25m. Payback time is also found to be in the range of 2.2 to 3.5 years, which reveals that the system is completely economically viable. In addition, the conducted 4E analysis shows that the optimum value of the air gap is around 0.15 m.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne tehničke znanosti
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split
Profili:
Sandro Nižetić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus