Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1209658

Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems


Šegulja, Dragana; Šparakl, Tajana; Rogić, Dunja
Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems // Scandinavian journal of clinical & laboratory investigation, 82 (2022), 2; 85-89 doi:10.1080/00365513.2022.2034035 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1209658 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems

Autori
Šegulja, Dragana ; Šparakl, Tajana ; Rogić, Dunja

Izvornik
Scandinavian journal of clinical & laboratory investigation (0036-5513) 82 (2022), 2; 85-89

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Capillary electrophoresis ; M components ; monoclonal gammopathy ; multiple myeloma ; sensitivity ; serum protein electrophoresis

Sažetak
Capillary electrophoresis is a method with a long history of developments which enables monitoring of several pathological processes and has an irreplaceable role in screening for presence of M- protein. The aim of this study was to assess analytical performance of Sebia and Helena systems, as well as their screening efficiency for M-protein by identifying characteristic electrophoretic pattern abnormalities. The controls were analyzed in triplicate over a five- day period. Comparability testing was performed on 46 (Capillarys3Octa) and 49 (V8Nexus) serum samples with routinely used Capillarys2. Electropherograms (EPGs) were reviewed by two specialists independently to select samples for further processing by immunofixation. All precision test results met the eligibility criteria by Ricos et al. The correlation coefficients higher than 0.8 indicated excellent comparability although the results were slightly more comparable among the same manufacturer systems. There were no variations in observed abnormalities in EPGs when Capillarys systems were compared, but a disparity was detected in 11/49 EPGs on comparing Capillarys2 and V8Nexus. The cause of the detected difference could be in a different graphical presentation of the findings and in a lesser resolution of the applied buffer. The impression is that the V8Nexus system combined with the utilized buffer provides greater resolution in the alpha-1 and alpha-2 globulin fractions, but that it declines in the gamma globulin fraction. The precision and estimated accuracy criteria were met by both systems. Comparison results implied that capillary systems are not equally effective in M-protein screening, highlighting the necessity to include system screening efficiency in analytical evaluation.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti, Farmacija



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Dunja Rogić (autor)

Avatar Url Dunja Rogić (autor)

Avatar Url Dragana Šegulja (autor)

Poveznice na cjeloviti tekst rada:

doi www.tandfonline.com doi.org

Citiraj ovu publikaciju:

Šegulja, Dragana; Šparakl, Tajana; Rogić, Dunja
Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems // Scandinavian journal of clinical & laboratory investigation, 82 (2022), 2; 85-89 doi:10.1080/00365513.2022.2034035 (međunarodna recenzija, članak, znanstveni)
Šegulja, D., Šparakl, T. & Rogić, D. (2022) Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems. Scandinavian journal of clinical & laboratory investigation, 82 (2), 85-89 doi:10.1080/00365513.2022.2034035.
@article{article, author = {\v{S}egulja, Dragana and \v{S}parakl, Tajana and Rogi\'{c}, Dunja}, year = {2022}, pages = {85-89}, DOI = {10.1080/00365513.2022.2034035}, keywords = {Capillary electrophoresis, M components, monoclonal gammopathy, multiple myeloma, sensitivity, serum protein electrophoresis}, journal = {Scandinavian journal of clinical and laboratory investigation}, doi = {10.1080/00365513.2022.2034035}, volume = {82}, number = {2}, issn = {0036-5513}, title = {Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems}, keyword = {Capillary electrophoresis, M components, monoclonal gammopathy, multiple myeloma, sensitivity, serum protein electrophoresis} }
@article{article, author = {\v{S}egulja, Dragana and \v{S}parakl, Tajana and Rogi\'{c}, Dunja}, year = {2022}, pages = {85-89}, DOI = {10.1080/00365513.2022.2034035}, keywords = {Capillary electrophoresis, M components, monoclonal gammopathy, multiple myeloma, sensitivity, serum protein electrophoresis}, journal = {Scandinavian journal of clinical and laboratory investigation}, doi = {10.1080/00365513.2022.2034035}, volume = {82}, number = {2}, issn = {0036-5513}, title = {Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems}, keyword = {Capillary electrophoresis, M components, monoclonal gammopathy, multiple myeloma, sensitivity, serum protein electrophoresis} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font