Pregled bibliografske jedinice broj: 1205256
Study of the impact of EMF on the reduction of biofouling in heat exchangers
Study of the impact of EMF on the reduction of biofouling in heat exchangers // Trends in Maritime Technology and Engineering Volume 1: Proceedings of the 6th International Conference on Maritime Technology and Engineering (MARTECH 2022, Lisbon, Portugal, 24-26 May 2022) / Guedes Soares, C. ; Santos, T. A. (ur.).
London : Delhi: CRC Press, 2022. str. 511-516 doi:10.1201/9781003320272 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1205256 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Study of the impact of EMF on the reduction of biofouling in heat exchangers
Autori
Boullosa-Falces, D. ; Gomez-Solaetxe, M.A. ; Sanchez Varela, Z. ; García, S. ; Trueba, A. ; Sanz, D.
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Trends in Maritime Technology and Engineering Volume 1: Proceedings of the 6th International Conference on Maritime Technology and Engineering (MARTECH 2022, Lisbon, Portugal, 24-26 May 2022)
/ Guedes Soares, C. ; Santos, T. A. - London : Delhi : CRC Press, 2022, 511-516
ISBN
9781003320272
Skup
6th International Conference on Maritime Technology and Engineering (MARTECH 2022)
Mjesto i datum
Lisabon, Portugal, 24.05.2022. - 26.05.2022
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Biofouling ; Heat exchanger ; Predictive maintenance ; Seawater
Sažetak
One of the biggest problems in equipment that uses water as a coolant is biofouling. In the design and operation of water-cooled heat exchangers, the biological coefficient must be considered, which adheres to the inside of the tubes, redcucing the efficiency of the equipment. For this reason, it is necessary to apply an appropriate antifouling treatment for the design of each heat exchanger. In this work, the effectiveness of electromagnetic field (EMF) to reduce the growth of biofouling adhering to the tubes of a seawater cooled heat exchanger will be evaluated. In a first phase the interior of the tubes of a seawater cooled heat exchanger was monitored using Cusum control charts until biofouling growth was established. In one of the tubes, the EMF treatment was applied continuously in order to maintain it in the initial condition. The control chart showed that the EMF treatment increased the useful life compared to the control tube without treatment.
Izvorni jezik
Engleski
Znanstvena područja
Tehnologija prometa i transport