Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 120196

Mjerenje, obrada i analiza EMG signala mišića lokomotornog sustava


Grujić-Šupuk, Tamara
Mjerenje, obrada i analiza EMG signala mišića lokomotornog sustava, 2003., magistarski rad, Fakultet elektrotehnike, strojarstva i bodogradnje, Split


CROSBI ID: 120196 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Mjerenje, obrada i analiza EMG signala mišića lokomotornog sustava
(Measurement, Processing and Analysis of EMG signals of locomotor muscles)

Autori
Grujić-Šupuk, Tamara

Vrsta, podvrsta i kategorija rada
Ocjenski radovi, magistarski rad

Fakultet
Fakultet elektrotehnike, strojarstva i bodogradnje

Mjesto
Split

Datum
25.04

Godina
2003

Stranica
119

Mentor
Zanchi, Vlasta

Ključne riječi
elektromiogram; emg sustav; biopojačalo; wavelet transformacija; uklanjanje šuma; intervali mišićne aktivnosti; inverzna dinamika
(electromyogram; emg system; bioamplifier; wavelet transformation; inverse dynamics)

Sažetak
This thesis deals with surface electromyography, which includes measurement, acquisition, processing and application of the emg signals. An emg system used for emg signals acquisition is designed, developed and tested. The design of bioamplifier is of particular significance in sense of noise reduction. Therefore, the low noise instrumentational amplifier with high CMRR of 130dB is chosen for the preamplifier. Processing of emg signals was performed by using several filtering methods, including wavelet based noise removal. Analysis of emg signals was focused on detection of muscle activation intervals during gait. The proposed method for detecting muscle activity is based on maximum voluntary contraction and application of thresholding. As the case example of the application of emg signals in biomechanics, the analysis of movement during gait was performed. The inverse dynamics approach which uses Newton-Euler’ s equations was implemented and joint forces and moments were calculated. Kinematic data, measured at the Laboratory of Biomedical Engineering and Robotics, at the Faculty of Electrical Engineering, University of Ljubljana, were used as input data for the calculation of moments. Finally, the comparison of joint moments and emg signals of the dominant leg muscles was done in order to identify the influence of particular muscles in generation of movement.

Izvorni jezik
Hrvatski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0023022

Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split

Profili:

Avatar Url Tamara Grujić (autor)

Avatar Url Vlasta Zanchi (mentor)


Citiraj ovu publikaciju:

Grujić-Šupuk, Tamara
Mjerenje, obrada i analiza EMG signala mišića lokomotornog sustava, 2003., magistarski rad, Fakultet elektrotehnike, strojarstva i bodogradnje, Split
Grujić-Šupuk, T. (2003) 'Mjerenje, obrada i analiza EMG signala mišića lokomotornog sustava', magistarski rad, Fakultet elektrotehnike, strojarstva i bodogradnje, Split.
@phdthesis{phdthesis, author = {Gruji\'{c}-\v{S}upuk, Tamara}, year = {2003}, pages = {119}, keywords = {elektromiogram, emg sustav, biopoja\v{c}alo, wavelet transformacija, uklanjanje \v{s}uma, intervali mi\v{s}i\'{c}ne aktivnosti, inverzna dinamika}, title = {Mjerenje, obrada i analiza EMG signala mi\v{s}i\'{c}a lokomotornog sustava}, keyword = {elektromiogram, emg sustav, biopoja\v{c}alo, wavelet transformacija, uklanjanje \v{s}uma, intervali mi\v{s}i\'{c}ne aktivnosti, inverzna dinamika}, publisherplace = {Split} }
@phdthesis{phdthesis, author = {Gruji\'{c}-\v{S}upuk, Tamara}, year = {2003}, pages = {119}, keywords = {electromyogram, emg system, bioamplifier, wavelet transformation, inverse dynamics}, title = {Measurement, Processing and Analysis of EMG signals of locomotor muscles}, keyword = {electromyogram, emg system, bioamplifier, wavelet transformation, inverse dynamics}, publisherplace = {Split} }




Contrast
Increase Font
Decrease Font
Dyslexic Font