Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1196842

Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography


Zjacic Puljiz, Danijela; Meštrović, Antonio; Žaja, Ivan; Grgurević, Ivica; Duplančić, Darko; Ljutić, Dragan; Delić JUkić, Ivana; Puljiz, Željko
Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography // Knjiga sažetaka
Split, Hrvatska, 2018. str. 29-29 (poster, podatak o recenziji nije dostupan, sažetak, znanstveni)


CROSBI ID: 1196842 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography

Autori
Zjacic Puljiz, Danijela ; Meštrović, Antonio ; Žaja, Ivan ; Grgurević, Ivica ; Duplančić, Darko ; Ljutić, Dragan ; Delić JUkić, Ivana ; Puljiz, Željko

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Knjiga sažetaka / - , 2018, 29-29

Skup
8. Kongres Hrvatskog gastroenterološkog društva

Mjesto i datum
Split, Hrvatska, 11.10.2018. - 14.10.2018

Vrsta sudjelovanja
Poster

Vrsta recenzije
Podatak o recenziji nije dostupan

Ključne riječi
liver stiffness, two-dimensional real time elastography

Sažetak
Analysis of impact of hemodialysis on liver stiffness measured with real time Two-dimensional shear wave elastography.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
KBC Split,
Medicinski fakultet, Split


Citiraj ovu publikaciju:

Zjacic Puljiz, Danijela; Meštrović, Antonio; Žaja, Ivan; Grgurević, Ivica; Duplančić, Darko; Ljutić, Dragan; Delić JUkić, Ivana; Puljiz, Željko
Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography // Knjiga sažetaka
Split, Hrvatska, 2018. str. 29-29 (poster, podatak o recenziji nije dostupan, sažetak, znanstveni)
Zjacic Puljiz, D., Meštrović, A., Žaja, I., Grgurević, I., Duplančić, D., Ljutić, D., Delić JUkić, I. & Puljiz, Ž. (2018) Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography. U: Knjiga sažetaka.
@article{article, author = {Zjacic Puljiz, Danijela and Me\v{s}trovi\'{c}, Antonio and \v{Z}aja, Ivan and Grgurevi\'{c}, Ivica and Duplan\v{c}i\'{c}, Darko and Ljuti\'{c}, Dragan and Deli\'{c} JUki\'{c}, Ivana and Puljiz, \v{Z}eljko}, year = {2018}, pages = {29-29}, keywords = {liver stiffness, two-dimensional real time elastography}, title = {Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography}, keyword = {liver stiffness, two-dimensional real time elastography}, publisherplace = {Split, Hrvatska} }
@article{article, author = {Zjacic Puljiz, Danijela and Me\v{s}trovi\'{c}, Antonio and \v{Z}aja, Ivan and Grgurevi\'{c}, Ivica and Duplan\v{c}i\'{c}, Darko and Ljuti\'{c}, Dragan and Deli\'{c} JUki\'{c}, Ivana and Puljiz, \v{Z}eljko}, year = {2018}, pages = {29-29}, keywords = {liver stiffness, two-dimensional real time elastography}, title = {Impact of hemodialysis on liver stiffness measured with real time two-dimensional shear wave elastography}, keyword = {liver stiffness, two-dimensional real time elastography}, publisherplace = {Split, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font