Pregled bibliografske jedinice broj: 119652
COMPARISON OF ARTERIAL STIFFNES - RESULTS OBTAINED WITH M MODE ULTRASOUND ANALYSIS AND THREE-DIMENSIONAL ULTRASOUND
COMPARISON OF ARTERIAL STIFFNES - RESULTS OBTAINED WITH M MODE ULTRASOUND ANALYSIS AND THREE-DIMENSIONAL ULTRASOUND // Cerebrovascular diseases, 16 (2003), s2. (podatak o recenziji nije dostupan, kongresno priopcenje, znanstveni)
CROSBI ID: 119652 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
COMPARISON OF ARTERIAL STIFFNES - RESULTS OBTAINED WITH M MODE ULTRASOUND ANALYSIS AND THREE-DIMENSIONAL ULTRASOUND
Autori
Kesic, Miljenka Jelena ; Lovrenčić Huzjan, Arijana ; Vukovic, Vlasta ; Morović, Sandra ; Zavoreo, Iris ; Lisak, Marijana ; Demarin, Vida
Izvornik
Cerebrovascular diseases (1015-9770) 16
(2003), S2;
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kongresno priopcenje, znanstveni
Ključne riječi
arterial stiffness; three dimensional ultrasound
Sažetak
Background: Arterial stiffnes is associated with generation of aterosclerosis and higher risk of stroke. Aim: The aim was to validate results of three-dimensional ultrasound (3D US) analysis in evaluation of common carotid artery (CCA) stiffness. Patients and methods: Ten individuals without known risk factors except smoking, underwent CCA M-mode ultrasound, high resolution B-mode ultrasound and 3D US investigation. M and B mode slices were obtained with 10 MHz linear array transducer. 3D data sets were obtained in standardized manner, free-handed in a defined period of time (10 seconds). Recorded images were reconstructed with TomTec imaging system, and measurement was done three times, mean value was calculated. CCA stiffness was assessed by measuring CCA distensibility, expressed as luminal strain (LS) and wall shear stress (WSS). Distensibility was calculated as difference between systolic and diastolic CCA diameter over diastolic lumen diameter. Data were analyzed by Kolmogorov-Smirnov one sample test using exponential distribution. Results: Mean intima-media thickness (IMT) was 0, 53 + 0, 13 mm on B-mode US (p<0, 5) , 0, 52 + 0, 16 on M mode (p<0, 5) and 0, 61 + 0, 14 on 3D US (p<0, 5). LS CCA stiffness by M-mode was 11, 4 + 5, 72 (p<0, 5), and with 3D US 10, 6 + 3, 55 (p<0, 5). WSS CCA stiffness by M-mode was 7, 66 + 2, 61 (p<0, 5), and with 3D US 9, 01 + 4, 84 (p<0, 5, for uniform distribution). Conclusion: The results indicate a good correlation of CCA stiffness between M-mode and 3D US.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
0134015
Ustanove:
KBC "Sestre Milosrdnice"
Profili:
Arijana Lovrenčić-Huzjan
(autor)
Vida Demarin
(autor)
Marijana Lisak
(autor)
Vlasta Vuković Cvetković
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE