Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1194821

Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM)


Kušurin, Marko; Majnarić, Matea; Unić, Daniel; Barić, Davor; Blažeković, Robert; Varvodić, Josip; Rudež, Igor
Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM) // The heart surgery forum, 24 (2021), 6; E963-E967 doi:10.1532/hsf.4265 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1194821 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM)

Autori
Kušurin, Marko ; Majnarić, Matea ; Unić, Daniel ; Barić, Davor ; Blažeković, Robert ; Varvodić, Josip ; Rudež, Igor

Izvornik
The heart surgery forum (1098-3511) 24 (2021), 6; E963-E967

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
coronary artery surgery ; transit time flow measurement ; OPCAB ; CABG

Sažetak
Objective: To compare the intraoperative quality of coronary anastomoses performed with or without cardio-pulmonary bypass using transit time flow measurement (TTFM) parameters.Methods: We collected data from 588 consecutive patients who underwent surgical revascularization. We retrospectively reviewed data from two groups: 411 with cardiopulmonary bypass (CABG group) and 177 off- pump (OPCABG group). Transit time flow measurement parameters: mean graft flow (MGF), pulsatile index (PI), and diastolic filing (DF) were measured for each graft and patient.Results: Patients in the OPCABG group had higher EuroSCORE compared with the CABG group (3.53 ± 2.32 versus 2.84 ± 2.15, P = .002). Overall comparison of TTFM parameters showed no statistical difference between the two surgical techniques except for PI in circumflex artery terri-tory, which was higher in the OPCABG group for all types of grafts 3.0 ± 4.9 versus 2.4 ± 2.0 in, P = .026.Conclusion: The comparison between OPCABG and CABG in this study showed comparable results with both surgical techniques. PI was higher in the OPCABG group in harder-to-reach vessel territories. Measurement of transit time may improve the quality, safety, and efficacy of coro-nary artery bypass grafting and should be considered as a routine procedure.

Izvorni jezik
Engleski

Znanstvena područja
Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinička bolnica "Dubrava"

Profili:

Avatar Url Igor Rudež (autor)

Avatar Url Robert Blažeković (autor)

Avatar Url Davor Barić (autor)

Avatar Url Daniel Unić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Kušurin, Marko; Majnarić, Matea; Unić, Daniel; Barić, Davor; Blažeković, Robert; Varvodić, Josip; Rudež, Igor
Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM) // The heart surgery forum, 24 (2021), 6; E963-E967 doi:10.1532/hsf.4265 (međunarodna recenzija, članak, znanstveni)
Kušurin, M., Majnarić, M., Unić, D., Barić, D., Blažeković, R., Varvodić, J. & Rudež, I. (2021) Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM). The heart surgery forum, 24 (6), E963-E967 doi:10.1532/hsf.4265.
@article{article, author = {Ku\v{s}urin, Marko and Majnari\'{c}, Matea and Uni\'{c}, Daniel and Bari\'{c}, Davor and Bla\v{z}ekovi\'{c}, Robert and Varvodi\'{c}, Josip and Rude\v{z}, Igor}, year = {2021}, pages = {E963-E967}, DOI = {10.1532/hsf.4265}, keywords = {coronary artery surgery, transit time flow measurement, OPCAB, CABG}, journal = {The heart surgery forum}, doi = {10.1532/hsf.4265}, volume = {24}, number = {6}, issn = {1098-3511}, title = {Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM)}, keyword = {coronary artery surgery, transit time flow measurement, OPCAB, CABG} }
@article{article, author = {Ku\v{s}urin, Marko and Majnari\'{c}, Matea and Uni\'{c}, Daniel and Bari\'{c}, Davor and Bla\v{z}ekovi\'{c}, Robert and Varvodi\'{c}, Josip and Rude\v{z}, Igor}, year = {2021}, pages = {E963-E967}, DOI = {10.1532/hsf.4265}, keywords = {coronary artery surgery, transit time flow measurement, OPCAB, CABG}, journal = {The heart surgery forum}, doi = {10.1532/hsf.4265}, volume = {24}, number = {6}, issn = {1098-3511}, title = {Comparison between OPCABG and CABG Surgical Revascularization Using Transit Time Flow Measurement (TTFM)}, keyword = {coronary artery surgery, transit time flow measurement, OPCAB, CABG} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font