Pregled bibliografske jedinice broj: 11923
Transient Analysis of Temperature Distribution in Furnace Walls
Transient Analysis of Temperature Distribution in Furnace Walls // Modelling, Simulation and Optimization / Kalpić, Damir ; Hljuz Dobrić, Vesna (ur.).
Pula, Hrvatska: Sveučilišni računski centar Sveučilišta u Zagrebu (Srce), 1998. str. 463-470 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 11923 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Transient Analysis of Temperature Distribution in Furnace Walls
Autori
Bogdan, Željko ; Jakoplić, Zlatko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Modelling, Simulation and Optimization
/ Kalpić, Damir ; Hljuz Dobrić, Vesna - : Sveučilišni računski centar Sveučilišta u Zagrebu (Srce), 1998, 463-470
Skup
20th International Conference on Information Technology Interfaces 98
Mjesto i datum
Pula, Hrvatska, 16.06.1998. - 19.06.1998
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
furnace heat accumulation; transient temperature distribution; mathematical modeling
Sažetak
The problem of transient temperature behavior of the steam generator evaporator tube walls caused by the feedwater system fallout is presented in this paper. The tubes are covered with brick material as to be protected from overheating in the first part of the furnace, while in the second part they are exposed directly to the hot gases. During normal operation the accumulated heat energy in the furnace wall may cause the tube wall temperature excursions in the shutdown period. The representative cutouts of the furnace walls in the three distinguished furnace positions are modeled by the code NISA with the purpose of obtaining transient temperature profiles across furnace walls. The steady-state conditions are tested and the results compared with the existing measurement data prior to the transient analysis. The tube wall temperatures really exceed maximum permissible temperature for the given tube material some 280 min after the feedwater system fallout has been shown by the transient analysis.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo
POVEZANOST RADA
Projekti:
120001
Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb
Profili:
Željko Bogdan
(autor)