Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1190309

Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes


Šimac, Brankica; Živković, Marcela; Tomičević, Marina; Žarak, Marko; Đerek, Lovorka
Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes // "Haematology, including haemostasis" Clinical Chemistry and Laboratory Medicine (CCLM), vol. 59, no. s1, 2021, pp. s485-s540.
München, Njemačka: Walter de Gruyter, 2021. str. S499-S499 doi:10.1515/cclm-2021-5021 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 1190309 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes

Autori
Šimac, Brankica ; Živković, Marcela ; Tomičević, Marina ; Žarak, Marko ; Đerek, Lovorka

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
"Haematology, including haemostasis" Clinical Chemistry and Laboratory Medicine (CCLM), vol. 59, no. s1, 2021, pp. s485-s540. / - : Walter de Gruyter, 2021, S499-S499

Skup
24th IFCC-EFLM European Congress of Clinical Chemistry and Laboratory Medicine (EuroMedlab 2021)

Mjesto i datum
München, Njemačka, 10.04.2022. - 14.04.2022

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
sepsis markers ; MDW ; K2-EDTA ; K3-EDTA

Sažetak
BACKGROUND-AIM: Monocyte Distribution Width (MDW) is a novel hematology parameter, which represents a measure of change inthe monocyte size distribution. Morphological changes of monocytes in sepsis show greater heterogeneity of themonocyte population and thus a higher MDW value. MDW provides significant added value along with currently usedsepsis markers (WBC, PCT, CRP, IL-6) for early sepsis screening. The clinical MDW cut-off of 20.0 was establishedthrough a blinded prospective multi-center pilot study using K2-EDTA venous whole blood samples. According to thisstudy, MDW values >20.0 should raise suspicion that sepsis is present or will develop in patients within twelve hoursof the Emergency Department (ED) presentation. The type of EDTA salt may affect the accuracy of cell counting andsizing. The aim of our study was to evaluate the impact of Beckton-Dickinson (BD) blood collection tubes containingK2-EDTA and K3-EDTA as anticoagulants on MDW values. METHODS: Blood samples from 158 apparently healthy individuals undergoing annual health checkups were collected in K2-EDTA and simultaneously in K3-EDTA test tubes. All samples were analyzed for CBC with differential within 30 minafter collection on a Beckman Coulter Unicel DxH 900 hematology analyzer. Data were tested for normality usingthe Kolmogorov–Smirnov test. The significance of differences between samples was assessed by Wilcoxon's pairedtest. P < 0.05 was considered statistically significant. Data are presented as medians and interquartile ranges. Bland-Altman plotting was performed to assess the comparability of results. Statistical analysis was performed using MedCalc 14.8.1.0 statistical software. RESULTS: The study included 158 participants, age 30 (18–58), 91 (57, 6%) males. For K2-EDTA tubes median MDW value was 16, 25(15, 38–17, 44) and for K3-EDTA tubes 17, 11 (16, 18–18, 42). A statistically significant difference was found comparingMDW values in K2- EDTA and K3-EDTA (P<0.001). Bland-Altman analysis revealed statistically significant constant(mean -0, 8 ; 95%CI -1, 03 to -0, 59) and proportional differences (mean -4, 8% ; 95%CI -6, 10 to -3, 52). Limits of agreement(±1.96 SD of differences) ranged from -3.6 to 1.9 for constant difference and -20, 9 to 11.2% for proportional difference, respectively. Most of the values were lower when measured in K2-EDTA then in K3-EDTA. CONCLUSIONS: K2-EDTA is recommended as the anticoagulant of choice for routine hematology testing by the International Council for Standardization in Hematology (ICSH) and Clinical Laboratory Standard Institute (CLSI). Although K2- EDTA isthe anticoagulant of choice, K3-EDTA tubes are still in widespread use. Our study provides evidence that there is astatistically significant difference between K2-EDTA and K3-EDTA MDW measurements.To accurately use of MDW asadditional marker for early sepsis screening, it is necessary to perform clinical outcome studies based on the impactof K3-EDTA on MDW measurements.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
Klinička bolnica "Dubrava"

Profili:

Avatar Url Marko Žarak (autor)

Avatar Url Marcela Živković (autor)

Avatar Url Brankica Šimac (autor)

Avatar Url Lovorka Đerek (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi www.degruyter.com

Citiraj ovu publikaciju:

Šimac, Brankica; Živković, Marcela; Tomičević, Marina; Žarak, Marko; Đerek, Lovorka
Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes // "Haematology, including haemostasis" Clinical Chemistry and Laboratory Medicine (CCLM), vol. 59, no. s1, 2021, pp. s485-s540.
München, Njemačka: Walter de Gruyter, 2021. str. S499-S499 doi:10.1515/cclm-2021-5021 (poster, međunarodna recenzija, sažetak, stručni)
Šimac, B., Živković, M., Tomičević, M., Žarak, M. & Đerek, L. (2021) Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes. U: "Haematology, including haemostasis" Clinical Chemistry and Laboratory Medicine (CCLM), vol. 59, no. s1, 2021, pp. s485-s540. doi:10.1515/cclm-2021-5021.
@article{article, author = {\v{S}imac, Brankica and \v{Z}ivkovi\'{c}, Marcela and Tomi\v{c}evi\'{c}, Marina and \v{Z}arak, Marko and \DJerek, Lovorka}, year = {2021}, pages = {S499-S499}, DOI = {10.1515/cclm-2021-5021}, keywords = {sepsis markers, MDW, K2-EDTA, K3-EDTA}, doi = {10.1515/cclm-2021-5021}, title = {Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes}, keyword = {sepsis markers, MDW, K2-EDTA, K3-EDTA}, publisher = {Walter de Gruyter}, publisherplace = {M\"{u}nchen, Njema\v{c}ka} }
@article{article, author = {\v{S}imac, Brankica and \v{Z}ivkovi\'{c}, Marcela and Tomi\v{c}evi\'{c}, Marina and \v{Z}arak, Marko and \DJerek, Lovorka}, year = {2021}, pages = {S499-S499}, DOI = {10.1515/cclm-2021-5021}, keywords = {sepsis markers, MDW, K2-EDTA, K3-EDTA}, doi = {10.1515/cclm-2021-5021}, title = {Monocyte distribution width (MDW) values measured in K2-EDTA and K3-EDTA test tubes}, keyword = {sepsis markers, MDW, K2-EDTA, K3-EDTA}, publisher = {Walter de Gruyter}, publisherplace = {M\"{u}nchen, Njema\v{c}ka} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font