Would turbine uprating be allowable with respect to cavitation? - An example of vibroacoustic diagnosis


Bajić, Branko
Would turbine uprating be allowable with respect to cavitation? - An example of vibroacoustic diagnosis // Third International Symposium on Cavitation, Proceedings, Vol. 1 / Michel, J.M ; Kato, H. (ur.).
Grenoble, Francuska, 1998. str. 359-362 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 11901 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Would turbine uprating be allowable with respect to cavitation? - An example of vibroacoustic diagnosis
(Would turbine uprating be allowable with respect to cavitation? : An example of vibroacoustic diagnosis)

Autori
Bajić, Branko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Third International Symposium on Cavitation, Proceedings, Vol. 1 / Michel, J.M ; Kato, H. - , 1998, 359-362

Skup
Third International Symposium on Cavitation

Mjesto i datum
Grenoble, Francuska, 07.04.1998. - 10.04.1998

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
cavitation; erosion; turbine; uprating

Sažetak
Velocity field disturbances at the inflow to the runner of a turbine caused by the stay and guide vanes alter the vibroacoustic cavitation signature. The telltale amplitude modulation can be a means to identify the incipient, weak, or moderate cavitation related to each vane/runner blade pair. An application of this method is presented identifying the turbine parts responsible for the increase of cavitation predicted when uprating a 60 MW Kaplan turbine.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
01920302

Ustanove:
Brodarski institut d.o.o.

Profili:

Avatar Url Branko Bajić (autor)


Citiraj ovu publikaciju:

Bajić, Branko
Would turbine uprating be allowable with respect to cavitation? - An example of vibroacoustic diagnosis // Third International Symposium on Cavitation, Proceedings, Vol. 1 / Michel, J.M ; Kato, H. (ur.).
Grenoble, Francuska, 1998. str. 359-362 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Bajić, B. (1998) Would turbine uprating be allowable with respect to cavitation? - An example of vibroacoustic diagnosis. U: Michel, J. & Kato, H. (ur.)Third International Symposium on Cavitation, Proceedings, Vol. 1.
@article{article, author = {Baji\'{c}, Branko}, year = {1998}, pages = {359-362}, keywords = {cavitation, erosion, turbine, uprating}, title = {Would turbine uprating be allowable with respect to cavitation? - An example of vibroacoustic diagnosis}, keyword = {cavitation, erosion, turbine, uprating}, publisherplace = {Grenoble, Francuska} }
@article{article, author = {Baji\'{c}, Branko}, year = {1998}, pages = {359-362}, keywords = {cavitation, erosion, turbine, uprating}, title = {Would turbine uprating be allowable with respect to cavitation? : An example of vibroacoustic diagnosis}, keyword = {cavitation, erosion, turbine, uprating}, publisherplace = {Grenoble, Francuska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font