Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1188642

Wind loads on tall buildings with porous double-skin façades


Melnjak, Petar
Wind loads on tall buildings with porous double-skin façades, 2022., diplomski rad, diplomski, Fakultet strojarstva i brodogradnje, Zagreb


CROSBI ID: 1188642 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Wind loads on tall buildings with porous double-skin façades

Autori
Melnjak, Petar

Vrsta, podvrsta i kategorija rada
Ocjenski radovi, diplomski rad, diplomski

Fakultet
Fakultet strojarstva i brodogradnje

Mjesto
Zagreb

Datum
01.04

Godina
2022

Stranica
101

Mentor
Kozmar, Hrvoje ; Bartoli, Gianni

Neposredni voditelj
Škvorc, Petar

Ključne riječi
Tall buildings ; porous double-skin façades ; wind loads ; wind-tunnel experiments

Sažetak
Porous double-skin façade (PDSF) systems have become common in high-performance buildings. A PDSF system consists of an inner impermeable façade and an outer permeable façade. A small gap between the two skins enables the wind flow. The aerodynamic characteristics of buildings equipped with PDSF systems of various porosities were studied in an urban environment. Experiments were conducted in a boundary layer wind tunnel (BLWT) at the Inter-University Research Centre on Building Aerodynamics and Wind Engineering (CRIACIV) at the University of Florence, Italy. Flow characteristics were determined using Pitot tubes and hot-wire anemometry system. Aerodynamic loads and surface pressures acting on the building model were measured using a high-frequency force balance (HFFB) and pressure taps on the inner skin of the building model, respectively. The results indicate that the PDSF system on a building in an urban environment does not affect the across-wind and along-wind moment coefficients, while the PDSF system exhibits a slightly negative effect on the power spectral density of the across-wind moment because the peak values are greater. Furthermore, the PDSF system proved to diminish the mean pressure coefficient peak and mean values on all building surfaces as well as the standard deviation of surface pressure fluctuations.

Izvorni jezik
Engleski

Znanstvena područja
Arhitektura i urbanizam, Građevinarstvo, Strojarstvo, Temeljne tehničke znanosti, Interdisciplinarne tehničke znanosti



POVEZANOST RADA


Projekti:
IP-2016-06-2017 - Opterećenja vjetra i mora na energetske konstrukcije (WESLO) (Kozmar, Hrvoje, HRZZ - 2016-06) ( CroRIS)

Profili:

Avatar Url Petar Škvorc (mentor)

Avatar Url Hrvoje Kozmar (mentor)


Citiraj ovu publikaciju:

Melnjak, Petar
Wind loads on tall buildings with porous double-skin façades, 2022., diplomski rad, diplomski, Fakultet strojarstva i brodogradnje, Zagreb
Melnjak, P. (2022) 'Wind loads on tall buildings with porous double-skin façades', diplomski rad, diplomski, Fakultet strojarstva i brodogradnje, Zagreb.
@phdthesis{phdthesis, author = {Melnjak, Petar}, year = {2022}, pages = {101}, keywords = {Tall buildings, porous double-skin fa\c{c}ades, wind loads, wind-tunnel experiments}, title = {Wind loads on tall buildings with porous double-skin fa\c{c}ades}, keyword = {Tall buildings, porous double-skin fa\c{c}ades, wind loads, wind-tunnel experiments}, publisherplace = {Zagreb} }
@phdthesis{phdthesis, author = {Melnjak, Petar}, year = {2022}, pages = {101}, keywords = {Tall buildings, porous double-skin fa\c{c}ades, wind loads, wind-tunnel experiments}, title = {Wind loads on tall buildings with porous double-skin fa\c{c}ades}, keyword = {Tall buildings, porous double-skin fa\c{c}ades, wind loads, wind-tunnel experiments}, publisherplace = {Zagreb} }




Contrast
Increase Font
Decrease Font
Dyslexic Font