Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 118501

Quantitative Evaluation of 2D-Chromatograms with CCD Camera


Petrović, Mira; Kaštelan-Macan, Marija; Babić, Sandra
Quantitative Evaluation of 2D-Chromatograms with CCD Camera // Proceedings of the 10th International Symposium on Instrumental Planar Chromatography / Nyredy, S. ; Szabady, B. ; Kaiser, R.E. ; Studer, A. (ur.).
Budakalasz: Research Institute for Medicinal Plants, 1998. str. 117-125 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 118501 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Quantitative Evaluation of 2D-Chromatograms with CCD Camera

Autori
Petrović, Mira ; Kaštelan-Macan, Marija ; Babić, Sandra

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 10th International Symposium on Instrumental Planar Chromatography / Nyredy, S. ; Szabady, B. ; Kaiser, R.E. ; Studer, A. - Budakalasz : Research Institute for Medicinal Plants, 1998, 117-125

Skup
The 10th International Symposium on Instrumental Planar Chromatography

Mjesto i datum
Visegrád, Mađarska, 16.05.1998. - 19.05.1998

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
two-dimensional TLC; CCD camera; quantitative analysis

Sažetak
A mixture of 10 pesticides: MCPA, atrazine, propham, chloropropham, ofurace, boyleton, boycon A, boycon B, tetramethrin and alpha-cypermethrin was separated on CN-precoated HPTLC plates using polar mobile phase (methanol-water) in 1st and nonpolar mobile phase (hexane-diethyl ether) in 2nd direction. Chromatograms were recorded with sensitive colour CCD camera and evaluated with CAMAG VideoScan software. Two quantification modes were compared: scanning of whole plate and scanning of manually defined bended tracks. The precision of video-densitometric quantitation of 2D-chromatogram expressed as repeatability of image capturing and track setting was determined. The lowest RSD was obtained when the image was captured at focal distance of 15 mm and F-stop number 2 and the chromatogram quantitatively evaluated using complete scaning with 30 tracks positioned without overlaping.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA



Citiraj ovu publikaciju:

Petrović, Mira; Kaštelan-Macan, Marija; Babić, Sandra
Quantitative Evaluation of 2D-Chromatograms with CCD Camera // Proceedings of the 10th International Symposium on Instrumental Planar Chromatography / Nyredy, S. ; Szabady, B. ; Kaiser, R.E. ; Studer, A. (ur.).
Budakalasz: Research Institute for Medicinal Plants, 1998. str. 117-125 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Petrović, M., Kaštelan-Macan, M. & Babić, S. (1998) Quantitative Evaluation of 2D-Chromatograms with CCD Camera. U: Nyredy, S., Szabady, B., Kaiser, R. & Studer, A. (ur.)Proceedings of the 10th International Symposium on Instrumental Planar Chromatography.
@article{article, author = {Petrovi\'{c}, Mira and Ka\v{s}telan-Macan, Marija and Babi\'{c}, Sandra}, year = {1998}, pages = {117-125}, keywords = {two-dimensional TLC, CCD camera, quantitative analysis}, title = {Quantitative Evaluation of 2D-Chromatograms with CCD Camera}, keyword = {two-dimensional TLC, CCD camera, quantitative analysis}, publisher = {Research Institute for Medicinal Plants}, publisherplace = {Visegr\'{a}d, Ma\djarska} }
@article{article, author = {Petrovi\'{c}, Mira and Ka\v{s}telan-Macan, Marija and Babi\'{c}, Sandra}, year = {1998}, pages = {117-125}, keywords = {two-dimensional TLC, CCD camera, quantitative analysis}, title = {Quantitative Evaluation of 2D-Chromatograms with CCD Camera}, keyword = {two-dimensional TLC, CCD camera, quantitative analysis}, publisher = {Research Institute for Medicinal Plants}, publisherplace = {Visegr\'{a}d, Ma\djarska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font