Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1184873

Comparison of self-sampling blood collection for N- glycosylation analysis


Cvetko, Ana; Tijardović, Marko; Bilandžija-Kuš, Iva; Gornik, Olga
Comparison of self-sampling blood collection for N- glycosylation analysis // BMC research notes, 15 (2022), 1; 61, 6 doi:10.1186/s13104-022-05958-9 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1184873 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of self-sampling blood collection for N- glycosylation analysis

Autori
Cvetko, Ana ; Tijardović, Marko ; Bilandžija-Kuš, Iva ; Gornik, Olga

Izvornik
BMC research notes (1756-0500) 15 (2022), 1; 61, 6

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Comparability ; Glycan analysis ; Plasma N-glycosylation ; Repeatability ; Self-sampling

Sažetak
Objective: Self-sampling of capillary blood provides easier sample collection, handling, and shipping compared to more invasive blood sampling via venepuncture. Recently, other means of capillary blood collection were introduced to the market, such as Neoteryx sticks and Noviplex cards. We tested the comparability of these two self-sampling methods, alongside dried blood spots (DBS), with plasma acquired from venepunctured blood in N-glycoprofling of total proteins. We have also tested the intra-day repeatability of the three mentioned self-sampling methods. Capillary blood collection with Neoteryx, Noviplex and DBS was done following the manufacturers’ instructions and N-glycoprofling of released, fluorescently labelled N-glycans was performed with ultra-performance liquid chromatography. Results: Comparability with plasma was assessed by calculating the relative deviance, which was 0.674 for DBS, 0.092 for Neoteryx sticks, and 0.069 for Noviplex cards. In repeatability testing, similar results were obtained, with Noviplex cards and Neoteryx sticks performing substantially better than DBS (CVs=4.831% and 7.098%, compared to 14.305%, respectively). Our preliminary study on the use of Neoteryx and Noviplex self-sampling devices in glycoanalysis demonstrates their satisfactory performance in both the comparability and repeatability testing, however, they should be further tested in larger collaborations and cohorts.

Izvorni jezik
Engleski

Znanstvena područja
Biologija, Temeljne medicinske znanosti



POVEZANOST RADA


Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
Klinički bolnički centar Zagreb

Profili:

Avatar Url Marko Tijardović (autor)

Avatar Url Olga Gornik Kljaić (autor)

Avatar Url Ana Cvetko (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Cvetko, Ana; Tijardović, Marko; Bilandžija-Kuš, Iva; Gornik, Olga
Comparison of self-sampling blood collection for N- glycosylation analysis // BMC research notes, 15 (2022), 1; 61, 6 doi:10.1186/s13104-022-05958-9 (međunarodna recenzija, članak, znanstveni)
Cvetko, A., Tijardović, M., Bilandžija-Kuš, I. & Gornik, O. (2022) Comparison of self-sampling blood collection for N- glycosylation analysis. BMC research notes, 15 (1), 61, 6 doi:10.1186/s13104-022-05958-9.
@article{article, author = {Cvetko, Ana and Tijardovi\'{c}, Marko and Biland\v{z}ija-Ku\v{s}, Iva and Gornik, Olga}, year = {2022}, pages = {6}, DOI = {10.1186/s13104-022-05958-9}, chapter = {61}, keywords = {Comparability, Glycan analysis, Plasma N-glycosylation, Repeatability, Self-sampling}, journal = {BMC research notes}, doi = {10.1186/s13104-022-05958-9}, volume = {15}, number = {1}, issn = {1756-0500}, title = {Comparison of self-sampling blood collection for N- glycosylation analysis}, keyword = {Comparability, Glycan analysis, Plasma N-glycosylation, Repeatability, Self-sampling}, chapternumber = {61} }
@article{article, author = {Cvetko, Ana and Tijardovi\'{c}, Marko and Biland\v{z}ija-Ku\v{s}, Iva and Gornik, Olga}, year = {2022}, pages = {6}, DOI = {10.1186/s13104-022-05958-9}, chapter = {61}, keywords = {Comparability, Glycan analysis, Plasma N-glycosylation, Repeatability, Self-sampling}, journal = {BMC research notes}, doi = {10.1186/s13104-022-05958-9}, volume = {15}, number = {1}, issn = {1756-0500}, title = {Comparison of self-sampling blood collection for N- glycosylation analysis}, keyword = {Comparability, Glycan analysis, Plasma N-glycosylation, Repeatability, Self-sampling}, chapternumber = {61} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Emerging Sources Citation Index (ESCI)
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font