Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1183777

Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy


Kraguljac, Darko; Aleksić, Antonina; Rade, Marinko
Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy // Artificial organs, 46 (2022), 3; 120-124 doi:10.1111/aor.14132 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1183777 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy

Autori
Kraguljac, Darko ; Aleksić, Antonina ; Rade, Marinko

Izvornik
Artificial organs (0160-564X) 46 (2022), 3; 120-124

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
cerebral palsy, CP, modified Ashwort scale, MAS, pendulum test, spasticity

Sažetak
Cerebral palsy (CP) is often accompanied by motor limitations, abnormal movements and spasticity. Precise and reproducible assessment of spasticity is essential for the selection and follow up of the therapeutic protocol. We used a new instrument from the company 3F—Fit Fabricando Faber comprising inertial measurement units at the shank and thigh, and two EMG recording units to record electromyographic signals from the hamstrings and quadriceps muscles. The study included 48 subjects diagnosed with cerebral palsy. We performed a pendulum test on each subject three times. The analysis of results showed that the new measure based on the PT recordings is highly correlated with the muscle tone in CP patients, and automatically distinguishes the type of spasticity (flexion or extension), relaxation rate and spasticity strength. The new measure showed sensitivity of the PT and indicates great potential of using the PT in the protocols for better control of spasticity in CP patients.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Osijek,
Sveučilište Jurja Dobrile u Puli

Profili:

Avatar Url Marinko Rade (autor)

Poveznice na cjeloviti tekst rada:

doi onlinelibrary.wiley.com

Citiraj ovu publikaciju:

Kraguljac, Darko; Aleksić, Antonina; Rade, Marinko
Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy // Artificial organs, 46 (2022), 3; 120-124 doi:10.1111/aor.14132 (međunarodna recenzija, članak, znanstveni)
Kraguljac, D., Aleksić, A. & Rade, M. (2022) Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy. Artificial organs, 46 (3), 120-124 doi:10.1111/aor.14132.
@article{article, author = {Kraguljac, Darko and Aleksi\'{c}, Antonina and Rade, Marinko}, year = {2022}, pages = {120-124}, DOI = {10.1111/aor.14132}, keywords = {cerebral palsy, CP, modified Ashwort scale, MAS, pendulum test, spasticity}, journal = {Artificial organs}, doi = {10.1111/aor.14132}, volume = {46}, number = {3}, issn = {0160-564X}, title = {Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy}, keyword = {cerebral palsy, CP, modified Ashwort scale, MAS, pendulum test, spasticity} }
@article{article, author = {Kraguljac, Darko and Aleksi\'{c}, Antonina and Rade, Marinko}, year = {2022}, pages = {120-124}, DOI = {10.1111/aor.14132}, keywords = {cerebral palsy, CP, modified Ashwort scale, MAS, pendulum test, spasticity}, journal = {Artificial organs}, doi = {10.1111/aor.14132}, volume = {46}, number = {3}, issn = {0160-564X}, title = {Validation of the pendulum test in the assessment of muscle tone in persons with cerebral palsy}, keyword = {cerebral palsy, CP, modified Ashwort scale, MAS, pendulum test, spasticity} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font