Pregled bibliografske jedinice broj: 1181793
Development and validation of an HPLC method for simultaneous determination of capsaicinoids and camphor in over-the-counter medication for topical use
Development and validation of an HPLC method for simultaneous determination of capsaicinoids and camphor in over-the-counter medication for topical use // Molecules, 27 (2022), 1261, 11 doi:10.3390/ molecules27041261 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1181793 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Development and validation of an HPLC method for
simultaneous determination of capsaicinoids and
camphor
in over-the-counter medication for topical use
Autori
Lalić, Martin ; Soldić, Ana ; Lalić, Andrija ; Lalić, Zdenka ; Sertić, Miranda
Izvornik
Molecules (1420-3049) 27
(2022);
1261, 11
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
capsaicin ; dihydrocapsaicin ; camphor ; HPLC ; validation ; OTC
Sažetak
A reverse-phase high-performance liquid chromatography method was developed to determine and quantify capsaicin (trans-8-methyl- N- vanillyl-6- nonenamid), dihydrocapsaicin (8- methyl-N-vanillylnonanamide), and camphor (trimethylbicyclo[2.2.1]heptan-2-one). It is applicable in analyses of over-the-counter (OTC) medications for topical use and raw materials such as chili pepper oleoresin. Chromatographic separation was carried out on a C18 column using an isocratic flow of the mobile phase containing acetonitrile and ultrapure water in a ratio of 2:3, with pH adjusted to 3.2 using glacial acetic acid, and a flow rate of 1.5 mL/min. The concentration of the eluting compounds was monitored by a diode-array detector at a wavelength of 281 nm. The method was evaluated for several validation parameters, including selectivity, accuracy (confidence intervals < 0.05%), repeatability, and intermediate precision. The limit of detection (LOD) was determined to be 0.070 g/mL for capsaicin, 0.211 g/mL for dihydrocapsaicin, and 0.060 g/mL for camphor. The limit of quantification (LOQ) was determined to be 0.212 g/mL for capsaicin, 0.640 g/mL for dihydrocapsaicin, and 0.320 g/mL for camphor. Linearity was set in the range of 2.5–200 g/mL for capsaicin and dihydrocapsaicin and 25–2000 g/mL for camphor. The suggested analytical method can be used for quality control of formulated pharmaceutical products containing capsaicinoids, camphor, and propolis.
Izvorni jezik
Engleski
Znanstvena područja
Farmacija
POVEZANOST RADA
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE