Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application


Mrvar, Primož; Kastelic, Sebastjan; Terčelj, Milan; Petrič, Mitja; Bauer, Branko; Mitrović, Danijel
Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application // International Journal of Metalcasting, 14 (2020), 3; 846-852 doi:10.1007/s40962-020-00459-6 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1178260 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application

Autori
Mrvar, Primož ; Kastelic, Sebastjan ; Terčelj, Milan ; Petrič, Mitja ; Bauer, Branko ; Mitrović, Danijel

Izvornik
International Journal of Metalcasting (1939-5981) 14 (2020), 3; 846-852

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
SiMoCr CGI ; thermal fatigue testing ; cracking ; damage analysis

Sažetak
SiMoCr CGI (compacted graphite iron) has the potential to be a cost-effective replacement for some hot working tool steel parts like shot sleeve in HPDC (High-Pressure Die Casting) applications. Thermal fatigue testing of SiMoCr CGI cast alloy was performed on Gleeble 1500D machine. Cracks were evaluated on non-nitrided and nitrided samples at test temperatures of 400 and 600 _C, after 1000, 2000 and 4000 thermal cycles. Samples were heated to prescribed test temperature and afterward cooled in computer-guided cycles. After the test, all the samples were axially and radially sectioned and cracks on cross sections were evaluated. Length of all cracks which occurred was measured and statistically evaluated, i.e., the average length of cracks and distribution of crack lengths were determined. At nitrided samples, higher values for average crack lengths were obtained while density of cracks was lower in comparison with non-nitrided samples.

Izvorni jezik
Engleski

Znanstvena područja
Metalurgija, Strojarstvo



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Branko Bauer (autor)

Poveznice na cjeloviti tekst rada:

doi link.springer.com

Citiraj ovu publikaciju:

Mrvar, Primož; Kastelic, Sebastjan; Terčelj, Milan; Petrič, Mitja; Bauer, Branko; Mitrović, Danijel
Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application // International Journal of Metalcasting, 14 (2020), 3; 846-852 doi:10.1007/s40962-020-00459-6 (međunarodna recenzija, članak, znanstveni)
Mrvar, P., Kastelic, S., Terčelj, M., Petrič, M., Bauer, B. & Mitrović, D. (2020) Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application. International Journal of Metalcasting, 14 (3), 846-852 doi:10.1007/s40962-020-00459-6.
@article{article, author = {Mrvar, Primo\v{z} and Kastelic, Sebastjan and Ter\v{c}elj, Milan and Petri\v{c}, Mitja and Bauer, Branko and Mitrovi\'{c}, Danijel}, year = {2020}, pages = {846-852}, DOI = {10.1007/s40962-020-00459-6}, keywords = {SiMoCr CGI, thermal fatigue testing, cracking, damage analysis}, journal = {International Journal of Metalcasting}, doi = {10.1007/s40962-020-00459-6}, volume = {14}, number = {3}, issn = {1939-5981}, title = {Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application}, keyword = {SiMoCr CGI, thermal fatigue testing, cracking, damage analysis} }
@article{article, author = {Mrvar, Primo\v{z} and Kastelic, Sebastjan and Ter\v{c}elj, Milan and Petri\v{c}, Mitja and Bauer, Branko and Mitrovi\'{c}, Danijel}, year = {2020}, pages = {846-852}, DOI = {10.1007/s40962-020-00459-6}, keywords = {SiMoCr CGI, thermal fatigue testing, cracking, damage analysis}, journal = {International Journal of Metalcasting}, doi = {10.1007/s40962-020-00459-6}, volume = {14}, number = {3}, issn = {1939-5981}, title = {Thermal Fatigue Testing of SiMoCr Compacted Graphite Cast Iron for HPDC Tooling Application}, keyword = {SiMoCr CGI, thermal fatigue testing, cracking, damage analysis} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font