Pregled bibliografske jedinice broj: 117770
Video-Densitometric Quantitation of Fluorescence Quenching on Totally Irradiated Thin-Layer Chromatographic Plates
Video-Densitometric Quantitation of Fluorescence Quenching on Totally Irradiated Thin-Layer Chromatographic Plates // Journal of AOAC International, 83 (2000), 6; 1457-1462 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 117770 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Video-Densitometric Quantitation of Fluorescence Quenching on Totally Irradiated Thin-Layer Chromatographic Plates
(Video-Densitometric Quantitation of Fluorescence Quenching on Totally Irradiated Thin-Layer)
Autori
Petrović, Mira ; Kaštelan-Macan, Marija ; Ivanković, Danijela ; Matečić, Sanja
Izvornik
Journal of AOAC International (1060-3271) 83
(2000), 6;
1457-1462
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
thin-layer chromatography; video-densitometric quantitation; pesticides
Sažetak
The influence of the instrumental settings of a video-imaging system on the quality of captured images studied. The performance of the Camag video documentation system was evaluated by mesuraments of fluorescence quenching of a model compound (the pesticide atrazine) in the UV spectral region. The effects of different camera settings (aperture and number of accumulated frames) on background response, baseline noise, and sensitivity and reproducibility of detection were studied for different commercial thin-layer chromatographic (TLC) and high performance TLC (HPTLC) plates. The results showed that as the number of frames, in other words, the image brightness and background response, increased, the sensitivity also increased, reaching a maximum at settings that gave an image of moderate luminosity. Additional frame accumulation caused a decrease in sensitivity. A similar pattern was observed by measuring the limit of detection (LOD). Ig the f-stop number (aperture) was too large, the image was too bright, and if the aperture was too small, the image was too dark. Both of these extremes resulted in higher LOD. However, good sensitivity does not necessarily mean a low detection limit because of the high baseline noise at the same capturing conditions. Evaluation of dark or moderately luminous video images gave more repeatable results than did evaluation of very bright images. With HPTLC silica gel plates, the relative standard deviation ranged from 1.8 to 2.5 % for settings that resulted in moderately bright images, and from 5-8 % for settings that resulted in bright images.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Profili:
Sanja Matečić Mušanić
(autor)
Mira Petrović
(autor)
Marija Kaštelan-Macan
(autor)
Danijela Ašperger
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE