Pregled bibliografske jedinice broj: 1172469
DESIGN AND PRODUCTION OF A MILLIREACTOR SYSTEM WITH A pH-SENSITIVE COATING
DESIGN AND PRODUCTION OF A MILLIREACTOR SYSTEM WITH A pH-SENSITIVE COATING // 27th Croatian Meeting of Chemists and Chemical Engineers - Book of abstracts / Marković, Dean ; Meštrović, Ernest ; Namjesnik, Danijel ; Tomašić, Vesna (ur.).
Zagreb: Hrvatsko kemijsko društvo, 2021. str. 309-309 (poster, recenziran, sažetak, znanstveni)
CROSBI ID: 1172469 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
DESIGN AND PRODUCTION OF A MILLIREACTOR SYSTEM
WITH A pH-SENSITIVE COATING
Autori
Marković, Marijan-Pere ; Cingesar, Ivan Karlo ; Kassal, Petar ; Vrsaljko, Domagoj
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
27th Croatian Meeting of Chemists and Chemical Engineers - Book of abstracts
/ Marković, Dean ; Meštrović, Ernest ; Namjesnik, Danijel ; Tomašić, Vesna - Zagreb : Hrvatsko kemijsko društvo, 2021, 309-309
Skup
27. hrvatski skup kemičara i kemijskih inženjera (27HSKIKI)
Mjesto i datum
Veli Lošinj, Hrvatska, 05.10.2021. - 08.10.2021
Vrsta sudjelovanja
Poster
Vrsta recenzije
Recenziran
Ključne riječi
Additive manufacturing ; millireactor ; sensor film
Sažetak
The aim of this work was to design a millireactor system and to coat the surface of the channel with a pH-responsive sensor film. The sol-gel method was used to prepare the sensor film. The main objective was to obtain a functional pH sensor film that shows a clear response in real time within the channels of the millireactor. For the sol-gel method, tetraethoxysilane (TEOS) and phenyltrimethoxysilane (FTMS) were used as precursors with ethanol as solvent, the reaction was acid catalyzed using hydrochloric acid and methyl red was used as pH indicator. The obtained sensor films were first tested on plates and then applied in millireactor channels. Both the test plates and the millireactors were fabricated using stereolithography (SLA) 3D- printing technology. Tests on the plates showed that excessive thickness of the film leads to cracking, which causes leaching of the indicator and detachment of the film from the surface. Therefore, different methods were used to obtain thinner films. The results show a change in the color of the sensor films with the change in the pH of the solution inside the channels of the millireactor (Fig. 1). The time interval of the change was 5 minutes.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Kemijsko inženjerstvo, Interdisciplinarne tehničke znanosti
POVEZANOST RADA
Projekti:
MZO-KK.01.1.1.04.0006 - Otpad i Sunce u službi fotokatalitičke razgradnje mikroonečišćivala u vodama (OS-Mi) (Grčić, Ivana; Vrsaljko, Domagoj; Gajović, Andreja; Brnardić, Ivan, MZO - KK.01.1.1.04) ( CroRIS)
Ustanove:
Fakultet kemijskog inženjerstva i tehnologije, Zagreb
Profili:
Marijan-Pere Marković
(autor)
Petar Kassal
(autor)
Ivan Karlo Cingesar
(autor)
Domagoj Vrsaljko
(autor)