Spectropotentiometric investigations od solvent polymer sensor membranes


Zwickl, T.; Schneider, B.; Federer, B.; Sokalski, T.; Lindner, E.; Schaller, U.; Cimerman, Zvjezdana; Pretsch, E.
Spectropotentiometric investigations od solvent polymer sensor membranes // Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods / Ricco, A ; Buttler, M.A ; Vanysek, P ; Horvai, G ; Silva, A.F. (ur.).
Pennington (NJ), Sjedinjene Američke Države: The Electrochemical Society (ECS), 1997. str. 1080-1089 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 11698 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Spectropotentiometric investigations od solvent polymer sensor membranes

Autori
Zwickl, T. ; Schneider, B. ; Federer, B. ; Sokalski, T. ; Lindner, E. ; Schaller, U. ; Cimerman, Zvjezdana ; Pretsch, E.

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods / Ricco, A ; Buttler, M.A ; Vanysek, P ; Horvai, G ; Silva, A.F. - : The Electrochemical Society (ECS), 1997, 1080-1089

Skup
Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods

Mjesto i datum
Pennington (NJ), Sjedinjene Američke Države, 1997

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Sažetak
Various time-dependent processes in the bulk of solvent polymer membranes based on plasticized poly(vinly chloride) are analyzed with a flow-through cell mounted on a microscope equipped with optical filters.A CCD camer is used to record pictures with a resolution of ca. 2 ?m. Water uptake of dry membranes is monitored through a new lipophilic water indicator. From time.dependent absorbance changes, an apparent water diffusion coefficient., D*H2O of 2x10-8 cm2 s-1 is determined. In contrast to earlier results obtained with hidrophilic water indicators, we found that D*H2O is not time-dependent and no light scattering owing to water droplets occurs in the bulk of the membrane. Recently, it has been shown that cation interference induces long-term potential drifts of H+- selective electrode membranes based on a lipopohilic chromoionophore. These drifts have been correlated with diffusion processes by simultaneously monitoring the concentration profiles od the protonated and unprotonated chromoionophore.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
119410

Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Zvjezdana Cimerman (autor)


Citiraj ovu publikaciju:

Zwickl, T.; Schneider, B.; Federer, B.; Sokalski, T.; Lindner, E.; Schaller, U.; Cimerman, Zvjezdana; Pretsch, E.
Spectropotentiometric investigations od solvent polymer sensor membranes // Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods / Ricco, A ; Buttler, M.A ; Vanysek, P ; Horvai, G ; Silva, A.F. (ur.).
Pennington (NJ), Sjedinjene Američke Države: The Electrochemical Society (ECS), 1997. str. 1080-1089 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Zwickl, T., Schneider, B., Federer, B., Sokalski, T., Lindner, E., Schaller, U., Cimerman, Z. & Pretsch, E. (1997) Spectropotentiometric investigations od solvent polymer sensor membranes. U: Ricco, A., Buttler, M., Vanysek, P., Horvai, G. & Silva, A. (ur.)Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods.
@article{article, author = {Zwickl, T. and Schneider, B. and Federer, B. and Sokalski, T. and Lindner, E. and Schaller, U. and Cimerman, Zvjezdana and Pretsch, E.}, year = {1997}, pages = {1080-1089}, keywords = {}, title = {Spectropotentiometric investigations od solvent polymer sensor membranes}, keyword = {}, publisher = {The Electrochemical Society (ECS)}, publisherplace = {Pennington (NJ), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Zwickl, T. and Schneider, B. and Federer, B. and Sokalski, T. and Lindner, E. and Schaller, U. and Cimerman, Zvjezdana and Pretsch, E.}, year = {1997}, pages = {1080-1089}, keywords = {}, title = {Spectropotentiometric investigations od solvent polymer sensor membranes}, keyword = {}, publisher = {The Electrochemical Society (ECS)}, publisherplace = {Pennington (NJ), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font