Pregled bibliografske jedinice broj: 11698
Spectropotentiometric investigations od solvent polymer sensor membranes
Spectropotentiometric investigations od solvent polymer sensor membranes // Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods / Ricco, A ; Buttler, M.A ; Vanysek, P ; Horvai, G ; Silva, A.F. (ur.).
Pennington (NJ), Sjedinjene Američke Države: The Electrochemical Society (ECS), 1997. str. 1080-1089 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 11698 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Spectropotentiometric investigations od solvent polymer sensor membranes
Autori
Zwickl, T. ; Schneider, B. ; Federer, B. ; Sokalski, T. ; Lindner, E. ; Schaller, U. ; Cimerman, Zvjezdana ; Pretsch, E.
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods
/ Ricco, A ; Buttler, M.A ; Vanysek, P ; Horvai, G ; Silva, A.F. - : The Electrochemical Society (ECS), 1997, 1080-1089
Skup
Symposium on Chemical and Biological Sensors and Analytical Electrochemical Methods
Mjesto i datum
Pennington (NJ), Sjedinjene Američke Države, 1997
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Sažetak
Various time-dependent processes in the bulk of solvent polymer membranes based on plasticized poly(vinly chloride) are analyzed with a flow-through cell mounted on a microscope equipped with optical filters.A CCD camer is used to record pictures with a resolution of ca. 2 ?m. Water uptake of dry membranes is monitored through a new lipophilic water indicator. From time.dependent absorbance changes, an apparent water diffusion coefficient., D*H2O of 2x10-8 cm2 s-1 is determined. In contrast to earlier results obtained with hidrophilic water indicators, we found that D*H2O is not time-dependent and no light scattering owing to water droplets occurs in the bulk of the membrane. Recently, it has been shown that cation interference induces long-term potential drifts of H+- selective electrode membranes based on a lipopohilic chromoionophore. These drifts have been correlated with diffusion processes by simultaneously monitoring the concentration profiles od the protonated and unprotonated chromoionophore.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
119410
Ustanove:
Prirodoslovno-matematički fakultet, Zagreb
Profili:
Zvjezdana Cimerman
(autor)