Influence of blast load on the bond characteristic of retrofitted RC slabs


Lukić, Sanja; Draganić, Hrvoje; Netinger Grubeša, Ivanka; Gazić, Goran
Influence of blast load on the bond characteristic of retrofitted RC slabs // Construction and building materials, 319 (2022), 126094, 10 doi:10.1016/j.conbuildmat.2021.126094 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1166410 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Influence of blast load on the bond characteristic of retrofitted RC slabs

Autori
Lukić, Sanja ; Draganić, Hrvoje ; Netinger Grubeša, Ivanka ; Gazić, Goran

Izvornik
Construction and building materials (0950-0618) 319 (2022); 126094, 10

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Fracture energy ; Fracture area ; Pull-off test ; Interface failure mode ; Glass fibre retrofit

Sažetak
Although structures are commonly designed for standard loads, they can experience extreme loads, such as intentional or accidental explosions. Structural elements are not designed to withstand such loads and are often retrofitted to provide a higher level of protection. In this study, RC slabs were coated with glass fibre textile- reinforced epoxy resin for a higher level of blast protection. The bond characteristics of the applied retrofit and concrete substrate were experimentally and theoretically analysed. Fracture analysis was based on the total fracture area, providing a more accurate determination of the retrofit and composite system fracture energy. Based on the obtained results, a retrofit system consisting of two layers of chopped strand glass mats impregnated with epoxy resin proved to be most effective in mitigating the blast load and enhancing RC slab residual capacity. A pull-off test was used to determine the retrofit–concrete interface mode of failure. The results indicated the existence of a proper bond between the retrofit and concrete substrate, providing continuous stress distribution and enhanced load capacity.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo



POVEZANOST RADA


Projekti:
HRZZ-UIP-2017-05-7041 - Otpornost stupova nadvožnjaka na djelovanje eksplozije (BLAST) (Draganić, Hrvoje, HRZZ ) ( CroRIS)

Ustanove:
Građevinski i arhitektonski fakultet Osijek

Profili:

Avatar Url Sanja Lukić (autor)

Avatar Url Ivanka Netinger (autor)

Avatar Url Hrvoje Draganić (autor)

Avatar Url Goran Gazić (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Lukić, Sanja; Draganić, Hrvoje; Netinger Grubeša, Ivanka; Gazić, Goran
Influence of blast load on the bond characteristic of retrofitted RC slabs // Construction and building materials, 319 (2022), 126094, 10 doi:10.1016/j.conbuildmat.2021.126094 (međunarodna recenzija, članak, znanstveni)
Lukić, S., Draganić, H., Netinger Grubeša, I. & Gazić, G. (2022) Influence of blast load on the bond characteristic of retrofitted RC slabs. Construction and building materials, 319, 126094, 10 doi:10.1016/j.conbuildmat.2021.126094.
@article{article, author = {Luki\'{c}, Sanja and Dragani\'{c}, Hrvoje and Netinger Grube\v{s}a, Ivanka and Gazi\'{c}, Goran}, year = {2022}, pages = {10}, DOI = {10.1016/j.conbuildmat.2021.126094}, chapter = {126094}, keywords = {Fracture energy, Fracture area, Pull-off test, Interface failure mode, Glass fibre retrofit}, journal = {Construction and building materials}, doi = {10.1016/j.conbuildmat.2021.126094}, volume = {319}, issn = {0950-0618}, title = {Influence of blast load on the bond characteristic of retrofitted RC slabs}, keyword = {Fracture energy, Fracture area, Pull-off test, Interface failure mode, Glass fibre retrofit}, chapternumber = {126094} }
@article{article, author = {Luki\'{c}, Sanja and Dragani\'{c}, Hrvoje and Netinger Grube\v{s}a, Ivanka and Gazi\'{c}, Goran}, year = {2022}, pages = {10}, DOI = {10.1016/j.conbuildmat.2021.126094}, chapter = {126094}, keywords = {Fracture energy, Fracture area, Pull-off test, Interface failure mode, Glass fibre retrofit}, journal = {Construction and building materials}, doi = {10.1016/j.conbuildmat.2021.126094}, volume = {319}, issn = {0950-0618}, title = {Influence of blast load on the bond characteristic of retrofitted RC slabs}, keyword = {Fracture energy, Fracture area, Pull-off test, Interface failure mode, Glass fibre retrofit}, chapternumber = {126094} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • INSPEC
  • Materials Science Citation Index


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font