Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1165069

Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation


Frljić, Stjepan; Trkulja, Bojan; Žiger, Igor
Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation // Applied Sciences-Basel, 11 (2021), 23; 11543, 15 doi:10.3390/app112311543 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1165069 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation

Autori
Frljić, Stjepan ; Trkulja, Bojan ; Žiger, Igor

Izvornik
Applied Sciences-Basel (2076-3417) 11 (2021), 23; 11543, 15

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
eddy currents ; eddy current losses ; lamination ; open-type transformer core ; numerical simulation ; FEM

Sažetak
Losses due to eddy currents in an open-type transformer core are significantly reduced by the lamination of the transformer core. In order to further reduce the eddy current losses, the open- type core often has a multi-part structure, i.e., it is composed of several more slender cores. The complete homogenization of such a core is not possible when an A, V−A formulation is used, where A and V represent the magnetic vector potential and electric scalar potential, respectively. On the other hand, an A, T −A formulation, where T represents the electric vector potential, enables the complete homogenization of the general open- type core, but the simulation converges poorly due to the large number of degrees of freedom. By eliminating the redundant degrees of freedom, the convergence rate is significantly improved, and is at least twice as good as the convergence rate of the simulation based on the A, V−A formulation. In this paper, a method for the calculation of the eddy current losses in an open-type core based on the A, T −A formulation with the elimination of redundant degrees of freedom is presented. The method is validated by comparison with a brute force simulation based on the A, V−A formulation, and the efficiency of the method is determined by comparison with the standard homogenization method based on the A, V−A formulation.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
HRZZ-IP-2020-02-2369 - Gubici uslijed vrtložnih struja u otvorenoj jezgri transformatora (GOJTRA) (Štih, Željko, HRZZ - 2020-02) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Stjepan Frljić (autor)

Avatar Url Bojan Trkulja (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi www.mdpi.com

Citiraj ovu publikaciju:

Frljić, Stjepan; Trkulja, Bojan; Žiger, Igor
Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation // Applied Sciences-Basel, 11 (2021), 23; 11543, 15 doi:10.3390/app112311543 (međunarodna recenzija, članak, znanstveni)
Frljić, S., Trkulja, B. & Žiger, I. (2021) Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation. Applied Sciences-Basel, 11 (23), 11543, 15 doi:10.3390/app112311543.
@article{article, author = {Frlji\'{c}, Stjepan and Trkulja, Bojan and \v{Z}iger, Igor}, year = {2021}, pages = {15}, DOI = {10.3390/app112311543}, chapter = {11543}, keywords = {eddy currents, eddy current losses, lamination, open-type transformer core, numerical simulation, FEM}, journal = {Applied Sciences-Basel}, doi = {10.3390/app112311543}, volume = {11}, number = {23}, issn = {2076-3417}, title = {Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation}, keyword = {eddy currents, eddy current losses, lamination, open-type transformer core, numerical simulation, FEM}, chapternumber = {11543} }
@article{article, author = {Frlji\'{c}, Stjepan and Trkulja, Bojan and \v{Z}iger, Igor}, year = {2021}, pages = {15}, DOI = {10.3390/app112311543}, chapter = {11543}, keywords = {eddy currents, eddy current losses, lamination, open-type transformer core, numerical simulation, FEM}, journal = {Applied Sciences-Basel}, doi = {10.3390/app112311543}, volume = {11}, number = {23}, issn = {2076-3417}, title = {Calculation of the Eddy Current Losses in a Laminated Open-Type Transformer Core Based on the A→,T→−A→ Formulation}, keyword = {eddy currents, eddy current losses, lamination, open-type transformer core, numerical simulation, FEM}, chapternumber = {11543} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font