Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1160646

Sulkus fiksacija savitljive intraokularne leće


Petric Ivanka, Mandić Zdravko, Lacmanović Loncar Valentina, Vatavuk Zoran, Skegro Irena, Skunca Jelena
Sulkus fiksacija savitljive intraokularne leće // Acta medica Croatica, 60 (2006), 2; 137-140 (domaća recenzija, članak, stručni)


CROSBI ID: 1160646 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Sulkus fiksacija savitljive intraokularne leće
(Sulcus fixation of a foldable acrylic intraocular lens)

Autori
Petric Ivanka, Mandić Zdravko, Lacmanović Loncar Valentina, Vatavuk Zoran, Skegro Irena, Skunca Jelena

Izvornik
Acta medica Croatica (1330-0164) 60 (2006), 2; 137-140

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni

Ključne riječi
sulkus fiksacija, savitljiva intraokularna leća
(sulcus fixatio, foldable intraocular lens)

Sažetak
Aim: To describe a surgical technique for sulcus fixation of a foldable single-piece acrylic intraocular lens (IOL) through a 3.0 mm clear cornea incision. Patients and methods: Between 2003 and 2004, this technique was used in 10 eyes at Sestre Milosrdnice University Hospital. Seven eyes were aphakic secondary to a capsule defect during phacoemulsification, one eye had a perforating injury with lens destruction, and two eyes were aphakic after congenital cataract extraction in childhood. In all eyes an AcrySof Natural SN60AT foldable single-piece acrylic IOL (Alcon, Forth Worth, TX, USA) was implanted. Results: The median age of patients at surgery was 41 (range 31-68) years, and the median follow up was 11 (range 4-18) months. In all cases, the intraocular lens was placed and fixed in the anatomic sulcus without complications. Slight IOL decentration (up to 1.0 mm) was seen in 2 eyes, and transient hypotonia and transient cystoid macular edema in 1 eye each. Discussion: In the absence of adequate posterior capsule support, scleral sutured posterior chamber intraocular lens implantation has become a popular technique. The reduction in incision, from 7 mm for the implantation of poly(methyl methacrylate) (PMMA) IOL to 3 mm for foldable IOL, represents an improvement in the technique, allowing for good postoperative vision recovery. Small incision helps maintain adequate intraoperative intraocular pressure in the anterior chamber. The design of single-piece AcrySof Natural lens allows for easy and safe fixation of the Prolene suture to the IOL. Also, this technique with scleral flaps that protects the exposed suture helps reduce the risk of endophthalmitis. Longer follow up is needed to ascertain the stability of this suture fixed IOL. Conclusion: Sulcus fixation of a foldable IOL offers an acceptable alternative for rehabilitation of vision function. The unique design characteristics of the single-piece AcrySof Natural IOL make possible the suture fixation through a small clear corneal incision.

Izvorni jezik
Hrvatski, engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA



Citiraj ovu publikaciju:

Petric Ivanka, Mandić Zdravko, Lacmanović Loncar Valentina, Vatavuk Zoran, Skegro Irena, Skunca Jelena
Sulkus fiksacija savitljive intraokularne leće // Acta medica Croatica, 60 (2006), 2; 137-140 (domaća recenzija, članak, stručni)
Petric Ivanka, Mandić Zdravko, Lacmanović Loncar Valentina, Vatavuk Zoran, Skegro Irena, Skunca Jelena (2006) Sulkus fiksacija savitljive intraokularne leće. Acta medica Croatica, 60 (2), 137-140.
@article{article, year = {2006}, pages = {137-140}, keywords = {sulkus fiksacija, savitljiva intraokularna le\'{c}a}, journal = {Acta medica Croatica}, volume = {60}, number = {2}, issn = {1330-0164}, title = {Sulkus fiksacija savitljive intraokularne le\'{c}e}, keyword = {sulkus fiksacija, savitljiva intraokularna le\'{c}a} }
@article{article, year = {2006}, pages = {137-140}, keywords = {sulcus fixatio, foldable intraocular lens}, journal = {Acta medica Croatica}, volume = {60}, number = {2}, issn = {1330-0164}, title = {Sulcus fixation of a foldable acrylic intraocular lens}, keyword = {sulcus fixatio, foldable intraocular lens} }

Časopis indeksira:


  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font