Pregled bibliografske jedinice broj: 1159576
Dynamic range optimization and noise reduction by low-sensitivity, fourth-order, band-pass filters using coupled general-purpose Biquads
Dynamic range optimization and noise reduction by low-sensitivity, fourth-order, band-pass filters using coupled general-purpose Biquads // Proceedings of the 2017 40th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO) / Biljanović, Petar et al. (ur.).
Opatija: Institute of Electrical and Electronics Engineers (IEEE), 2017. str. 141-145 doi:10.23919/MIPRO.2017.7973406 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1159576 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Dynamic range optimization and noise reduction by low-sensitivity, fourth-order, band-pass filters using coupled general-purpose Biquads
Autori
Emanović, Edi ; Jurišić, Dražen
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 2017 40th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)
/ Biljanović, Petar et al. - Opatija : Institute of Electrical and Electronics Engineers (IEEE), 2017, 141-145
ISBN
978-953-233-090-8
Skup
2017 40th International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)
Mjesto i datum
Opatija, Hrvatska, 22.05.2017. - 26.05.2017
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Cascade of Biquadratic sections ; Biquartic section ; Butterworth approximation ; band-pass filters ; general-purpose section ; sensitivity ; output thermal noise ; dynamic range
Sažetak
In this paper we compare two realisations of fourth-order band-pass filter sections: first is realized as a coupled structure, having negative feedback around two Biquadratic sections in cascade (CO), second is a common design of two Biquadratic sections in cascade (CA). Dynamic range optimization by equating opamp output voltage levels using signal-flow graph is presented for a single second-order GP-Biquad and for a fourth-order coupled Biquads. The reduction of sensitivity and noise is already well-known for the case of CO BP filter, with identical Biquads, when compared to the CA design. In this paper, it is shown that equating opamp output voltage levels reduces output noise even more. In that way, dynamic range is improved substantially. Because we use a general-purpose (GP) Biquad using two integrators, we can use its simple tuning features and simple design ; design equations are given. Sensitivity and output thermal noise are simulated using circuit analysis program Pspice.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
HRZZ-IP-2016-06-1307 - Frakcionalni analogni i mješoviti sustavi obrade signala (FractalAnalogFilters) (Jurišić, Dražen, HRZZ ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb