Pregled bibliografske jedinice broj: 1156166
Assessment of Timber Roof Structures before and after Earthquakes
Assessment of Timber Roof Structures before and after Earthquakes // Buildings, 11 (2021), 11; 1431416, 23 doi:10.3390/buildings11110528 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1156166 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Assessment of Timber Roof Structures before and
after Earthquakes
Autori
Perković, Nikola ; Stepniac, Mislav ; Rajčić, Vlatka ; Barbalić, Jure
Izvornik
Buildings (2075-5309) 11
(2021), 11;
1431416, 23
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
inspection ; assessment ; timber roof ; seismic area ; earthquake ; case study ; Zagreb
Sažetak
The global objective of sustainable development has been greatly directed toward the preservation of existing structures. Therefore, condition assessment and reconstruction of existing timber structures have been gaining importance in recent times. This is particularly evident on timber roofs whose elements are exposed to degradation, either because of rheological effects or due to the direct influence of moisture and biological factors. In case of accidental events, such as an earthquake, the question of the structure’s condition is essential for the condition of the entire building. In order to prove the load-bearing capacity and serviceability of existing structures, as well as to check the need for reconstruction, it is necessary to define crucial parameters that are influencing the condition of materials, elements, and systems. Although there are many non destructive testing methods, the frequency and scope of their use, as well as the decision-making approach, have not been defined. In the paper, non- destructive and semi-destructive methods frequently used for timber structures are explained. A systematic review of criteria to be used in the assessment of load-bearing timber structures in a seismic active area was the main objective of this paper as well as the illustration of non- destructive and semi-destructive test methods through a case study involving roof construction of a hundred-year-old building in Zagreb, Croatia. Pre- and post-earthquake inspection was made. The overall condition of the roof structure after two significant earthquakes can be assessed as satisfactory given that the observed system is a large-span and massive roof structure. The presented results and identification of typical damages after the earthquake are presented in order to facilitate policy makers and for the future implementation of development strategies in the renovation of the city.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo, Interdisciplinarne tehničke znanosti, Drvna tehnologija
POVEZANOST RADA
Projekti:
UIP-2019-04-3749 - Procjena stanja i obnova postojećih građevina - Razvoj suvremenih metoda za zidane i drvene konstrukcije (ARES) (Stepinac, Mislav, HRZZ - 2019-04) ( CroRIS)
Profili:
Vlatka Rajčić
(autor)
Nikola Perković
(autor)
Mislav Stepinac
(autor)
Jure Barbalić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- Social Science Citation Index (SSCI)
- SCI-EXP, SSCI i/ili A&HCI
- Emerging Sources Citation Index (ESCI)
- Scopus