Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids


Boras, Vedran; Berberović , Sead; Nikolovski , Srete
Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids // 26th International Conference on Lightning Protection Conference Proceedings
Krakov: Association of Polish Electrical Engineers, 2002. str. 388-393 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 115548 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids

Autori
Boras, Vedran ; Berberović , Sead ; Nikolovski , Srete

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
26th International Conference on Lightning Protection Conference Proceedings / - Krakov : Association of Polish Electrical Engineers, 2002, 388-393

Skup
26th International Conference on Lightning Protection

Mjesto i datum
Kraków, Poljska, 02.09.2002. - 06.09.2002

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
grounding grid; grounding impedance; mutual impedance; non-equipotential

Sažetak
This paper presents a more accurate mathematical modelling of the non-equipotential large grounding system at power frequency, which includes transversal mutual conductances between grounding segments as well as longitudinal mutual impedances. Numerical calculation of the grounding current field is based on the point collocation method with current density approximation by the second-degree polynomials and two-layer soll model. The method of images is used for solving the boundary value problem. Using the direct solution of a system of linear equations (matrix inversion), unknown coefficients of the current density approximation along all grounding elements and unknown potential values at nodal and collocation points are obtained. Such accurate modelling also enables more accurate computation of the grounding impedance. This procedure is applied in determining the inductance of the rectangular grids with uniform square meshes. The calculation is applied to the rectangular grids usually used in high voltage substations. The calculation results obtained by the propsed model are compared to the results obtained by other models and to the results of the analysis performed on the similar cases.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0036024

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Vedran Boras (autor)

Avatar Url Sead Berberović (autor)

Avatar Url Srete Nikolovski (autor)


Citiraj ovu publikaciju:

Boras, Vedran; Berberović , Sead; Nikolovski , Srete
Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids // 26th International Conference on Lightning Protection Conference Proceedings
Krakov: Association of Polish Electrical Engineers, 2002. str. 388-393 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Boras, V., Berberović , S. & Nikolovski , S. (2002) Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids. U: 26th International Conference on Lightning Protection Conference Proceedings.
@article{article, author = {Boras, Vedran and Berberovi\'{c}, Sead and Nikolovski, Srete}, year = {2002}, pages = {388-393}, keywords = {grounding grid, grounding impedance, mutual impedance, non-equipotential}, title = {Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids}, keyword = {grounding grid, grounding impedance, mutual impedance, non-equipotential}, publisher = {Association of Polish Electrical Engineers}, publisherplace = {Krak\'{o}w, Poljska} }
@article{article, author = {Boras, Vedran and Berberovi\'{c}, Sead and Nikolovski, Srete}, year = {2002}, pages = {388-393}, keywords = {grounding grid, grounding impedance, mutual impedance, non-equipotential}, title = {Improved numerical calculations of grounding system parameters in non-equipotential AC substation grouding grids}, keyword = {grounding grid, grounding impedance, mutual impedance, non-equipotential}, publisher = {Association of Polish Electrical Engineers}, publisherplace = {Krak\'{o}w, Poljska} }