Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1155137

The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses


Opačić, Dalibor; Miljak, Snježana; Ćuruvija-Opačić, Ksenija
The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses, 2015. (popularni rad).


CROSBI ID: 1155137 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses

Autori
Opačić, Dalibor ; Miljak, Snježana ; Ćuruvija-Opačić, Ksenija

Vrsta, podvrsta
Ostale vrste radova, popularni rad

Godina
2015

Ključne riječi
astigmatism ; RGP contact lenses

Sažetak
The aim of this study was to calculate the level of improvement of visual acuity comparing the best corrected visual acuity (VA) achieved with spectacles with the best corrected VA achieved with rigid gas permeable (RGP) contact lenses in patients with high, simple or compound corneal astigmatism (myopic, hypermetropic and mixed). The investigation of patients included auto-kerato-refractometry, manual keratometry, corneal topography and visual acuity with Snellen chart. The best corrected VA obtained with spectacles was compared with the best corrected VA obtained with RGP contact lenses in 72 patients (116 eyes). All patients showed a signifi cant improvement in visual acuity with RGP lenses from one to seven lines compared to spectacles (p=0.0001). Level of improvement in VA represented as the number of lines obtained was as follows: 74 percent of patients got two to four lines more in VA with RGP lenses compared to spectacles, and almost 10 percent of patients got fi ve to seven lines. RGP contact lenses provide a signifi cant improvement in VA compared to VA reached with spectacles in patients with high corneal astigmatism. The benefi t in VA with RGP lenses is higher as the astigmatism is higher.

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Dalibor Opačić (autor)


Citiraj ovu publikaciju:

Opačić, Dalibor; Miljak, Snježana; Ćuruvija-Opačić, Ksenija
The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses, 2015. (popularni rad).
Opačić, D., Miljak, S. & Ćuruvija-Opačić, K. (2015) The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses.. Popularni rad.
@unknown{unknown, author = {Opa\v{c}i\'{c}, Dalibor and Miljak, Snje\v{z}ana and \'{C}uruvija-Opa\v{c}i\'{c}, Ksenija}, year = {2015}, keywords = {astigmatism, RGP contact lenses}, title = {The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses}, keyword = {astigmatism, RGP contact lenses} }
@unknown{unknown, author = {Opa\v{c}i\'{c}, Dalibor and Miljak, Snje\v{z}ana and \'{C}uruvija-Opa\v{c}i\'{c}, Ksenija}, year = {2015}, keywords = {astigmatism, RGP contact lenses}, title = {The Level of Improvement of Visual Acuity in High Corneal Astigmatism with Rigid Gas Permeable Contact Lenses}, keyword = {astigmatism, RGP contact lenses} }




Contrast
Increase Font
Decrease Font
Dyslexic Font