Pregled bibliografske jedinice broj: 1155065
Investigation on the electric field strength radiated from G.fast data carrying copper telecommunication network
Investigation on the electric field strength radiated from G.fast data carrying copper telecommunication network // Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku, 28 (2021), 1; 38-44 doi:10.17559/tv-20190315093013 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1155065 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Investigation on the electric field strength
radiated from G.fast data carrying copper
telecommunication network
Autori
Milanović, Josip ; Rimac-Drlje, Snježana
Izvornik
Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku (1330-3651) 28
(2021), 1;
38-44
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
ECC/REC/(05)04 ; FCC Volume 47 Part 15 ; G.fast ; ITU-T K.60 ; radio frequency interference
Sažetak
G.fast technology provides low cost ultra-fast broadband by transmitting high frequency signals through existing copper telecommunication network. Unfortunately, copper telecommunication network is not originally designed for data transmission on high frequencies, resulting with cable radiation when G.fast signal is transmitted. This radiation can interfere with radio services operating in the same frequency range and cause serious disturbances of the radio signal reception, thus disabling radio services to operate as intended. In order to limit radiation from telecommunication network various limits have been proposed. This paper gives the comparison between defined radiation limits and measurements of the E-field radiation from the unshielded copper telecommunication cable (TK 33-U) when G.fast (profile 106a) signal is transmitted. The results show that limit values proposed in ITU-T K.60 and FCC Volume 47 Part 15 recommendation overestimate while radiation limits proposed in ECC/REC/(05)04 recommendation underestimate radiation from TK 33- U cable. Additionally, measurement results show that E-field strength is below the ITU and FCC recommended limits, even when the unbalanced cable is used.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus