Pregled bibliografske jedinice broj: 1150674
Comparison of new versus reused Harmonic scalpel performance in laparoscopic appendectomy in patients with acute appendicitis—a randomized clinical trial
Comparison of new versus reused Harmonic scalpel performance in laparoscopic appendectomy in patients with acute appendicitis—a randomized clinical trial // Langenbeck's Archives of Surgery, 406 (2020), 1; 153-162 doi:10.1007/s00423-020-02039-y (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1150674 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of new versus reused Harmonic scalpel performance in laparoscopic appendectomy in patients with acute appendicitis—a randomized clinical trial
Autori
Mihanović, Jakov ; Šikić, Nataša Lisica ; Mrklić, Ivana ; Katušić, Zvonimir ; Karlo, Robert ; Jukić, Miro ; Jerončić, Ana ; Pogorelić, Zenon
Izvornik
Langenbeck's Archives of Surgery (1435-2443) 406
(2020), 1;
153-162
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
new ; used ; Harmonic scalpel ; laparoscopic appendectomy ; acute appendicitis
Sažetak
Background The aim of this study was to compare lateral thermal damage of the appendix and clinical outcomes after laparoscopic appendectomy using new versus reused Harmonic scalpels. Methods A total of 100 consecutive patients with acute appendicitis who underwent laparoscopic appendectomy were enrolled in the two-center, randomized clinical trial. Using a computer random number generator, patients were allocated to new or reused group. Histopathological measurement of lateral thermal damage of the appendiceal base and mesoappendix, speed of transection of the appendiceal base, duration of surgery, subjective rating of device functionality, length of hospital stay, and complications were compared within groups. Results The median lateral thermal damage on the appendiceal base in the new group (N = 49) was 0.2 mm (IQR 0.1–0.2) and 0.1 mm (IQR 0.1–0.3) in the reused group (N = 51) (P = 0.644), while on the mesoappendix for both groups, thermal damage was 0.1 mm (IQR 0.1–0.2) (P = 0.418). The median time required for base transection in both groups was 8 s (IQR 7–9) (P = 0.776). The median duration of surgery was also comparable between the groups (22 min, IQR 20–30 vs 25 min, IQR 21–35 ; P = 0.233). Two postoperative complications in the new group and one in the reused group were recorded (4% vs 2% ; P = 0.536). Surgeons’ subjective assessment of the instrument did not reveal significant difference between the groups in all of the investigated categories. Conclusions The results of our study support the reuse of Harmonic scalpels especially in the settings where economic constraints might hamper access to minimally invasive surgery to a larger number of patients. The results obtained on laparoscopic appendectomy might not be reproducible to other more demanding surgical procedures. Trial registration ClinicalTrials.gov registry under identifier NCT04226482
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
KBC Split,
Medicinski fakultet, Split,
Sveučilište u Zadru,
Opća bolnica Zadar
Profili:
Zenon Pogorelić
(autor)
Nataša Lisica-Šikić
(autor)
Ana Jerončić
(autor)
Ivana Mrklić
(autor)
Jakov Mihanović
(autor)
Miro Jukić
(autor)
Robert Karlo
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE