Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles


Draganić, Hrvoje; Gazić, Goran; Lukić, Sanja; Jeleč, Mario
Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles // Composite structures, 274 (2021), 114349, 20 doi:10.1016/j.compstruct.2021.114349 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1140952 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles

Autori
Draganić, Hrvoje ; Gazić, Goran ; Lukić, Sanja ; Jeleč, Mario

Izvornik
Composite structures (0263-8223) 274 (2021); 114349, 20

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Static tests ; Field blast tests ; Blast mitigation ; Glass fiber textile polymer

Sažetak
Blast mitigation of civil and transportation infrastructure is in focus due to the ever‐present volatile geopoliticalsituation. Structures are not designed to withstand blast load, and in areas of an imminent attack, their sensi-tive elements require blast retrofit. The retrofit technique selected follows three criteria: speed and ease ofapplication and relatively low price. Commercially available glassfibers, in the form of textiles and mats, wereapplied on RC slabs using epoxy resin. The test program consisted of two phases. Thefirst phase consisted oflaboratory four‐ point static bending tests of RC slabs to determine the feasibility and efficiency of devised retro- fit. The second phase consisted offield blast tests of RC slabs to study blast behavior and determine the appli-cability of devised retrofits. Applied retrofit has been proved useful in reducingflying debris and maximumdeflection in the tested range of explosion.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo, Temeljne tehničke znanosti



POVEZANOST RADA


Projekti:
HRZZ-UIP-2017-05-7041 - Otpornost stupova nadvožnjaka na djelovanje eksplozije (BLAST) (Draganić, Hrvoje, HRZZ ) ( CroRIS)

Ustanove:
Građevinski i arhitektonski fakultet Osijek

Profili:

Avatar Url Mario Jeleč (autor)

Avatar Url Sanja Lukić (autor)

Avatar Url Goran Gazić (autor)

Avatar Url Hrvoje Draganić (autor)

Citiraj ovu publikaciju:

Draganić, Hrvoje; Gazić, Goran; Lukić, Sanja; Jeleč, Mario
Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles // Composite structures, 274 (2021), 114349, 20 doi:10.1016/j.compstruct.2021.114349 (međunarodna recenzija, članak, znanstveni)
Draganić, H., Gazić, G., Lukić, S. & Jeleč, M. (2021) Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles. Composite structures, 274, 114349, 20 doi:10.1016/j.compstruct.2021.114349.
@article{article, author = {Dragani\'{c}, Hrvoje and Gazi\'{c}, Goran and Luki\'{c}, Sanja and Jele\v{c}, Mario}, year = {2021}, pages = {20}, DOI = {10.1016/j.compstruct.2021.114349}, chapter = {114349}, keywords = {Static tests, Field blast tests, Blast mitigation, Glass fiber textile polymer}, journal = {Composite structures}, doi = {10.1016/j.compstruct.2021.114349}, volume = {274}, issn = {0263-8223}, title = {Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles}, keyword = {Static tests, Field blast tests, Blast mitigation, Glass fiber textile polymer}, chapternumber = {114349} }
@article{article, author = {Dragani\'{c}, Hrvoje and Gazi\'{c}, Goran and Luki\'{c}, Sanja and Jele\v{c}, Mario}, year = {2021}, pages = {20}, DOI = {10.1016/j.compstruct.2021.114349}, chapter = {114349}, keywords = {Static tests, Field blast tests, Blast mitigation, Glass fiber textile polymer}, journal = {Composite structures}, doi = {10.1016/j.compstruct.2021.114349}, volume = {274}, issn = {0263-8223}, title = {Experimental investigation on blast load resistance of reinforced concrete slabs retrofitted with epoxy resin impregnated glass fiber textiles}, keyword = {Static tests, Field blast tests, Blast mitigation, Glass fiber textile polymer}, chapternumber = {114349} }