Pregled bibliografske jedinice broj: 1139184
Validation of the UDI-6 and the ICIQ-UI SF – Croatian version
Validation of the UDI-6 and the ICIQ-UI SF – Croatian version // International Urogynecology Journal, 31 (2020), 12; 2625-2630 doi:10.1007/s00192-020-04500-4 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1139184 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Validation of the UDI-6 and the ICIQ-UI SF –
Croatian version
Autori
Mikuš, Mislav ; Ćorić, Mario ; Matak, Luka ; Škegro, Bernarda ; Vujić, Goran ; Banović, Vladimir
Izvornik
International Urogynecology Journal (0937-3462) 31
(2020), 12;
2625-2630
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
ICIQ-UI SF ; UDI-6 ; Urinary incontinence ; Validation.
Sažetak
Introduction and hypothesis: Despite the widespread use of UDI-6 and ICIQ-UI SF in Croatia, it remains unknown whether a realiable and valid measure for the population of interest is used. Thus, the aim of this study was to translate, adapt and validate the UDI-6 and the ICIQ-UI SF in Croatia. Methods: The study included a total of 232 consecutive patients with urinary incontinence symptoms. The translation to Croatian followed standardized procedure. All participants underwent urodynamic assesment and completed UDI-6 and ICIQ- UI SF questionnaires at inclusion and 2 weeks after to assess test-retest reliability. Cronbach α coefficient was calculated in order to assess internal consistency. Results: Both questionnaires had high internal consistency (Cronbach α for UDI- 6 and ICIQ-UI SF was .83 and .85, respectively) and high test-retest reliability (intraclass correlation coefficient .99 for instruments). Strong correlation was found between urodynamic findings and total scores in UDI-6 and ICIQ-UI SF (ρ = 0.88 and 0.89, respectively). Women with stress urinary incontinence (SUI) and detrusor overactivity (DOA) group had significantly higher scores on UDI-6 (Mdn = 33.33 and Mdn = 50, respectively) compared to women with no urodynamic abnormality (Mdn = 0 ; p < 0.001). Women with no urodynamic abnormality scored significantly lower on ICIQ-UI SF (Mdn = 0 ; p < 0.001) compared to women with SUI (Mdn = 14) and DOA (Mdn = 16). Women with DOA scored worse on Irritative and Obstructive symptoms when comparing with two other groups (p < 0.001), while women with SUI had significantly worse score on Stress symptoms subscale (p < 0.001). Conclusions: The UDI-6 and ICIQ-UI SF have very good psychometric characteristics and can be used in Croatian urogynecology practice. Keywords: ICIQ-UI SF ; UDI-6 ; Urinary incontinence ; Validation.
Izvorni jezik
Engleski
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
KBC "Sestre Milosrdnice",
Klinički bolnički centar Zagreb,
Medicinski fakultet, Osijek,
Opća bolnica Zadar
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE