Pregled bibliografske jedinice broj: 112879
Bilateral cochlear function in Croatia
Bilateral cochlear function in Croatia // Danube Symposium International Otorhinolaryngologic Congress: Abstract Book / . (ur.).
Dubrovnik, 2002. (predavanje, nije recenziran, sažetak, znanstveni)
CROSBI ID: 112879 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Bilateral cochlear function in Croatia
(Bilateral cochlear implantation in Croatia)
Autori
Trotić, R. ; Pegan, B. ; Kakić, B. ; Ries, M. ; Šindija, B. ; Bedeković, V. ; Kalogjera, I. ; Ivkić, M.
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Danube Symposium International Otorhinolaryngologic Congress: Abstract Book
/ . - Dubrovnik, 2002
Skup
Danube Symposium International Otorhinolaryngologic Congress
Mjesto i datum
Dubrovnik, Hrvatska, 16.10.2002. - 19.10.2002
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Nije recenziran
Ključne riječi
.
Sažetak
Intorduction: The Croatian cochlear Implant Programme began in 1996. in Department of Otorhinolaryngology Sestre milordnice University Hospital in Zagreb.Until June 2002. we have 106 patients with cochlear implants, one with auditory brainstem implant and one with bilateral cochlear implants.Bilateral cochlear implantation (BiCI) offers the potential to improve patient performance.The field of BiCI presents a hos of additional complexities and opportunities for both researchers and patients.Research on the improvement of speech understanding of implanted patients has concentrated primarily on unilateral cochlear implantations.Case description: The 20-year-old patient had been deaf for 10 years due to posttraumatic meningitis.With best fitted hearing aids on both sides during 10 years after meningitis, he was able to perceive acoustic sounds on 85&#8211 ; ; 125 dB between 125 and 1000 Hz.In 2000. he received both COMBI 40+ cochlear implants in a single operation.Results:6 months after fitting, the patient reached PTA on left ear between 25 and 90 dB, on right ear between 20 and 50 dB.With BiCI numbers, colours, words close set, word open set, sentences close set and sentences open set were between 90% and 100%.Signal to noise ratio exam &#8211 ; ; 10 dB SPL showed 80% score in sentences open set, and 100% sentences closed set with BiCI.Conclusion:BiCI in croatian patient showed significant improvement of speech understanding in quite and noise, and the patient benefited with BiCI better than with unilateral CI.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti, Farmacija
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb,
Poliklinika SUVAG
Profili:
Robert Trotić
(autor)
Mirko Ivkić
(autor)
Mihael Ries
(autor)
Biserka Pegan
(autor)
Ante Kalogjera
(autor)
Branka Šindija
(autor)
Gordan Bedeković
(autor)