Pregled bibliografske jedinice broj: 1128058
The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics
The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics // Sensors, 21 (2021), 10; 1-12 doi:10.3390/s21103535 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1128058 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The influence of plasticizers on the response
characteristics of the surfactant sensor for
cationic surfactant determination in
disinfectants and antiseptics
Autori
Sakač, Nikola ; Madunić-Čačić, Dubravka ; Karnaš, Maja ; Đurin, Bojan ; Kovač, Ivan ; Jozanović, Marija
Izvornik
Sensors (1424-8220) 21
(2021), 10;
1-12
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
plasticizer ; sensor ; potentiometry ; antiseptic ; cationic surfactant ; disinfectant
Sažetak
Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB as an ionophore, six different plasticizers [2-nitrophenyl-octyl-ether (P1), bis(2-ethylhexyl) phthalate (P2), bis(2- ethylhexyl) sebacate (P3), 2-nitrophenyl phenyl ether (P4), dibutyl phthalate (P5) and dibutyl sebacate (P6)] and a PVC to produce ionic surfactant sensors. Sensor formulation with P1 showed the best potentiometric response to four usually used cationic surfactant, with the lowest LOD, 7 × 10−7 M ; and potentiometric titration curves with well-defined and sharp inflexion points. The sensor with P6 showed the lowest analytical performances. Surfactant sensor with P1 was selected for quantification of cationic surfactant in model solutions and commercial samples of disinfectants and antiseptics. It showed high accuracy and precision in all determinations, with recovery from 98.2 to 99.6, and good agreement with the results obtained with surfactant sensor used as a referent one, and a standard two-phase titration method. RDS values were lower than 0.5% for all determinations.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Kemijsko inženjerstvo, Temeljne tehničke znanosti
POVEZANOST RADA
Ustanove:
Fakultet agrobiotehničkih znanosti Osijek,
Geotehnički fakultet, Varaždin,
Sveučilište u Osijeku - Odjel za kemiju,
Sveučilište Sjever, Koprivnica
Profili:
Marija Jozanović
(autor)
Dubravka Madunić-Čačić
(autor)
Ivan Kovač
(autor)
Maja Karnaš
(autor)
Nikola Sakač
(autor)
Bojan Đurin
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE