Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1128058

The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics


Sakač, Nikola; Madunić-Čačić, Dubravka; Karnaš, Maja; Đurin, Bojan; Kovač, Ivan; Jozanović, Marija
The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics // Sensors, 21 (2021), 10; 1-12 doi:10.3390/s21103535 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1128058 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics

Autori
Sakač, Nikola ; Madunić-Čačić, Dubravka ; Karnaš, Maja ; Đurin, Bojan ; Kovač, Ivan ; Jozanović, Marija

Izvornik
Sensors (1424-8220) 21 (2021), 10; 1-12

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
plasticizer ; sensor ; potentiometry ; antiseptic ; cationic surfactant ; disinfectant

Sažetak
Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB as an ionophore, six different plasticizers [2-nitrophenyl-octyl-ether (P1), bis(2-ethylhexyl) phthalate (P2), bis(2- ethylhexyl) sebacate (P3), 2-nitrophenyl phenyl ether (P4), dibutyl phthalate (P5) and dibutyl sebacate (P6)] and a PVC to produce ionic surfactant sensors. Sensor formulation with P1 showed the best potentiometric response to four usually used cationic surfactant, with the lowest LOD, 7 × 10−7 M ; and potentiometric titration curves with well-defined and sharp inflexion points. The sensor with P6 showed the lowest analytical performances. Surfactant sensor with P1 was selected for quantification of cationic surfactant in model solutions and commercial samples of disinfectants and antiseptics. It showed high accuracy and precision in all determinations, with recovery from 98.2 to 99.6, and good agreement with the results obtained with surfactant sensor used as a referent one, and a standard two-phase titration method. RDS values were lower than 0.5% for all determinations.

Izvorni jezik
Engleski

Znanstvena područja
Kemija, Kemijsko inženjerstvo, Temeljne tehničke znanosti



POVEZANOST RADA


Ustanove:
Fakultet agrobiotehničkih znanosti Osijek,
Geotehnički fakultet, Varaždin,
Sveučilište u Osijeku - Odjel za kemiju,
Sveučilište Sjever, Koprivnica

Poveznice na cjeloviti tekst rada:

doi www.mdpi.com

Citiraj ovu publikaciju:

Sakač, Nikola; Madunić-Čačić, Dubravka; Karnaš, Maja; Đurin, Bojan; Kovač, Ivan; Jozanović, Marija
The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics // Sensors, 21 (2021), 10; 1-12 doi:10.3390/s21103535 (međunarodna recenzija, članak, znanstveni)
Sakač, N., Madunić-Čačić, D., Karnaš, M., Đurin, B., Kovač, I. & Jozanović, M. (2021) The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics. Sensors, 21 (10), 1-12 doi:10.3390/s21103535.
@article{article, author = {Saka\v{c}, Nikola and Maduni\'{c}-\v{C}a\v{c}i\'{c}, Dubravka and Karna\v{s}, Maja and \DJurin, Bojan and Kova\v{c}, Ivan and Jozanovi\'{c}, Marija}, year = {2021}, pages = {1-12}, DOI = {10.3390/s21103535}, keywords = {plasticizer, sensor, potentiometry, antiseptic, cationic surfactant, disinfectant}, journal = {Sensors}, doi = {10.3390/s21103535}, volume = {21}, number = {10}, issn = {1424-8220}, title = {The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics}, keyword = {plasticizer, sensor, potentiometry, antiseptic, cationic surfactant, disinfectant} }
@article{article, author = {Saka\v{c}, Nikola and Maduni\'{c}-\v{C}a\v{c}i\'{c}, Dubravka and Karna\v{s}, Maja and \DJurin, Bojan and Kova\v{c}, Ivan and Jozanovi\'{c}, Marija}, year = {2021}, pages = {1-12}, DOI = {10.3390/s21103535}, keywords = {plasticizer, sensor, potentiometry, antiseptic, cationic surfactant, disinfectant}, journal = {Sensors}, doi = {10.3390/s21103535}, volume = {21}, number = {10}, issn = {1424-8220}, title = {The influence of plasticizers on the response characteristics of the surfactant sensor for cationic surfactant determination in disinfectants and antiseptics}, keyword = {plasticizer, sensor, potentiometry, antiseptic, cationic surfactant, disinfectant} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font