Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method


Stipetić, Nina; Filipović-Grčić, Božidar; Uglešić, Ivo; Xemard, Alain; Andres, Naum
Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method // Electric power systems research, 197 (2021), 1-7 doi:10.1016/j.epsr.2021.107313 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1126697 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method

Autori
Stipetić, Nina ; Filipović-Grčić, Božidar ; Uglešić, Ivo ; Xemard, Alain ; Andres, Naum

Izvornik
Electric power systems research (0378-7796) 197 (2021); 1-7

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Isolated network ; Earth-fault ; Directional earth-fault protection ; Low-frequency signal injection

Sažetak
Neutral earthing directly affects systems’ behaviour regarding the maximum level of earth- fault current and overvoltages. Isolated neutral is used where continuity of power supply is essential, which is often the case in industrial power utilities. Although the system can remain in service during a single-phase earth-fault, locating the fault should be done as quickly as possible, without disrupting the operation of the loads. Directional earth-fault protection (67N) can be used to indicate the faulty feeder. An alternative method is low- frequency (LF) current injection combined with sensors for detecting the injected signal, which is a known technique used in LV systems. In this paper, the application of 67N protection and the LF current injection method are tested on the same MV system with inaccessible neutral point. Inductive voltage transformers (IVTs) are used for signal injection. Both methods are discussed, and their limitations are compared based on simulation results obtained using the model of an isolated MV industrial plant. The model includes relay protection devices and IVTs for signal injection.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika

Napomena
We have created a Share Link – a personalized
URL providing 50 days' free access to the
article. Anyone clicking on this link before
June 30, 2021 will be taken directly to the
final version of article on ScienceDirect,
which they are welcome to read or download. No
sign up, registration or fees are required
Download link:
https://authors.elsevier.com/c/1d2gR1M7~0mWx3



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Poveznice na cjeloviti tekst rada:

doi authors.elsevier.com www.sciencedirect.com

Citiraj ovu publikaciju:

Stipetić, Nina; Filipović-Grčić, Božidar; Uglešić, Ivo; Xemard, Alain; Andres, Naum
Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method // Electric power systems research, 197 (2021), 1-7 doi:10.1016/j.epsr.2021.107313 (međunarodna recenzija, članak, znanstveni)
Stipetić, N., Filipović-Grčić, B., Uglešić, I., Xemard, A. & Andres, N. (2021) Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method. Electric power systems research, 197, 1-7 doi:10.1016/j.epsr.2021.107313.
@article{article, author = {Stipeti\'{c}, Nina and Filipovi\'{c}-Gr\v{c}i\'{c}, Bo\v{z}idar and Ugle\v{s}i\'{c}, Ivo and Xemard, Alain and Andres, Naum}, year = {2021}, pages = {1-7}, DOI = {10.1016/j.epsr.2021.107313}, keywords = {Isolated network, Earth-fault, Directional earth-fault protection, Low-frequency signal injection}, journal = {Electric power systems research}, doi = {10.1016/j.epsr.2021.107313}, volume = {197}, issn = {0378-7796}, title = {Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method}, keyword = {Isolated network, Earth-fault, Directional earth-fault protection, Low-frequency signal injection} }
@article{article, author = {Stipeti\'{c}, Nina and Filipovi\'{c}-Gr\v{c}i\'{c}, Bo\v{z}idar and Ugle\v{s}i\'{c}, Ivo and Xemard, Alain and Andres, Naum}, year = {2021}, pages = {1-7}, DOI = {10.1016/j.epsr.2021.107313}, keywords = {Isolated network, Earth-fault, Directional earth-fault protection, Low-frequency signal injection}, journal = {Electric power systems research}, doi = {10.1016/j.epsr.2021.107313}, volume = {197}, issn = {0378-7796}, title = {Earth-fault detection and localization in isolated industrial MV network – comparison of directional overcurrent protection and signal injection method}, keyword = {Isolated network, Earth-fault, Directional earth-fault protection, Low-frequency signal injection} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font