Pregled bibliografske jedinice broj: 1126691
Determination of Cost-Effectiveness of the CO2- EOR and CO2 Utilization Factor as Feasibility Indicators for Permanent CO2 Storage
Determination of Cost-Effectiveness of the CO2- EOR and CO2 Utilization Factor as Feasibility Indicators for Permanent CO2 Storage, 2020., postdiplomski specijalisticki, Faculty of Mining, Geology and Petroleum Engineering, Zagreb
CROSBI ID: 1126691 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Determination of Cost-Effectiveness of the CO2-
EOR and CO2 Utilization Factor as Feasibility
Indicators for Permanent CO2 Storage
Autori
José García Lamberg, Gabriela
Vrsta, podvrsta i kategorija rada
Ocjenski radovi, postdiplomski specijalisticki
Fakultet
Faculty of Mining, Geology and Petroleum Engineering
Mjesto
Zagreb
Datum
02.11
Godina
2020
Stranica
22
Mentor
Vulin, Domagoj
Ključne riječi
CO2EOR ; CCUS ; CO2Retention ; Utilization Factor ; WAG ; EU-ETS
Sažetak
Carbon Capture Utilization and Storage (CCUS) is an effective technology for achieving climate change goals. As part of CCUS, CO2 - enhanced oil recovery results with permanent storage of significant amounts of CO2 and is an attractive technique for oil companies, with the main goal to maximize oil production, and minimize the injected CO2. For this investigation, oil production and retention were observed and compared in 72 reservoir simulation cases with an economic evaluation considering Utilization Factor (UF) and Net Present Value (NPV) which was assessed with different scenarios of CO2 and oil prices (32 scenarios, which, with observed simulation results totals in 1728 cases for economical evaluation). The cases were generated with three different WAG ratios, three permeabilities, two well distances and three depths, each with its specific pressure and temperature conditions. This was set to see the impact of the miscibility on oil production and CO2 sequestration and therefore finding the most optimal case. It was observed that well distances have a significant impact on retention and NPV, being the smaller distance arrange the most favourable for retention in observed period (15 years of CO2-EOR) and considering all aspects, the greatest benefit comes from cases that are at 1545 m with WAG ratio of 1:2 and permeability of 50 mD. Optimum (cost-effective) CO2 EOR cases all result with higher amount of CO2 stored, with 1.8 to 6.7 times CO2 storage capacity increase, compared to the respective cases without CO2-EOR.
Izvorni jezik
Engleski
Znanstvena područja
Rudarstvo, nafta i geološko inženjerstvo
POVEZANOST RADA
Projekti:
EK-H2020-653718 - ENabling Onshore CO2 Storage in Europe (ENOS) (Saftić, Bruno, EK - H2020-LCE-2015-1-two-stage) ( CroRIS)
EK-H2020-837754 - Strategic Planning of Regions and Territories in Europe for Low-Carbon Energy and Industry Through CCUS (STRATEGY CCUS) (Vulin, Domagoj, EK - H2020-LC-SC3-2018-NZE-CC) ( CroRIS)
Ustanove:
Rudarsko-geološko-naftni fakultet, Zagreb
Profili:
Domagoj Vulin
(mentor)