Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1126211

Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle


Plavec, Eduard; Petrinić, Miroslav; Vidović, Mladen
Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle // Journal of Electromagnetic Engineering and Science, 21 (2021), 2; 95-103 doi:10.26866/jees.2021.21.2.95 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1126211 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle

Autori
Plavec, Eduard ; Petrinić, Miroslav ; Vidović, Mladen

Izvornik
Journal of Electromagnetic Engineering and Science (2671-7255) 21 (2021), 2; 95-103

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
DC Electromagnetic Actuator, Force Characteristic, Lower Core Angle, Time Response

Sažetak
The aim of almost any electromagnetic actuator development is to increase the electromagnetic force with which an actuator acts on a plunger with as fast a time response as possible while maintaining the dimensions as small as possible. This paper presents research on the impact of the lower core angle on the force and time response of a DC solenoid electromagnetic actuator. The research method is based on the analytical analysis of the magnetic path of the DC solenoid electromagnetic actuator and a comparison with the numerical simulation results. A transient numerical simulation was performed on a 2D axial-symmetric model of the electromagnetic actuator and included simultaneously solving time-dependent partial differential equations of the electromagnetic actuator’s magnetic, electrical, and mechanical subsystems. The magnetic subsystem was analyzed by the finite element method (FEM) using the ANSYS Electronics software package. The three prototype models with different lower core angles were produced and tested in the accredited Laboratory Center of KONČAR Electrical Engineering Institute. The obtained measurements are compared with the analytical results and numerical simulation results.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
KONČAR - Institut za elektrotehniku d.d.

Profili:

Avatar Url Miroslav Petrinić (autor)

Avatar Url Mladen Vidović (autor)

Avatar Url Eduard Plavec (autor)

Poveznice na cjeloviti tekst rada:

doi www.jees.kr

Citiraj ovu publikaciju:

Plavec, Eduard; Petrinić, Miroslav; Vidović, Mladen
Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle // Journal of Electromagnetic Engineering and Science, 21 (2021), 2; 95-103 doi:10.26866/jees.2021.21.2.95 (međunarodna recenzija, članak, znanstveni)
Plavec, E., Petrinić, M. & Vidović, M. (2021) Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle. Journal of Electromagnetic Engineering and Science, 21 (2), 95-103 doi:10.26866/jees.2021.21.2.95.
@article{article, author = {Plavec, Eduard and Petrini\'{c}, Miroslav and Vidovi\'{c}, Mladen}, year = {2021}, pages = {95-103}, DOI = {10.26866/jees.2021.21.2.95}, keywords = {DC Electromagnetic Actuator, Force Characteristic, Lower Core Angle, Time Response}, journal = {Journal of Electromagnetic Engineering and Science}, doi = {10.26866/jees.2021.21.2.95}, volume = {21}, number = {2}, issn = {2671-7255}, title = {Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle}, keyword = {DC Electromagnetic Actuator, Force Characteristic, Lower Core Angle, Time Response} }
@article{article, author = {Plavec, Eduard and Petrini\'{c}, Miroslav and Vidovi\'{c}, Mladen}, year = {2021}, pages = {95-103}, DOI = {10.26866/jees.2021.21.2.95}, keywords = {DC Electromagnetic Actuator, Force Characteristic, Lower Core Angle, Time Response}, journal = {Journal of Electromagnetic Engineering and Science}, doi = {10.26866/jees.2021.21.2.95}, volume = {21}, number = {2}, issn = {2671-7255}, title = {Improving the Force and Time Response of a DC Solenoid Electromagnetic Actuator by Changing the Lower Core Angle}, keyword = {DC Electromagnetic Actuator, Force Characteristic, Lower Core Angle, Time Response} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font