Pregled bibliografske jedinice broj: 1122045
A Novel Passive Interface Circuit With Gain for Nongenerating Sensors in Differential or Bridge Configuration
A Novel Passive Interface Circuit With Gain for Nongenerating Sensors in Differential or Bridge Configuration // IEEE Transactions on Instrumentation and Measurement, 70 (2021), 2003008, 8 doi:10.1109/TIM.2021.3050160 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1122045 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
A Novel Passive Interface Circuit With Gain for Nongenerating Sensors in Differential or Bridge Configuration
Autori
Vyroubal, Darko
Izvornik
IEEE Transactions on Instrumentation and Measurement (0018-9456) 70
(2021);
2003008, 8
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
active sensor, bridge sensor configuration, differential sensor, gain, passive circuit, sensor interface
Sažetak
A novel passive interface circuit with gain for non-generating (active, i.e. excited/driven) sensors in differential or bridge configuration is presented. The circuit is very simple and consists of only one transformer in the output diagonal of the equivalent bridge configuration comprised of sensor(s), bridge completion impedances and excitation source. It can be used with resistive, capacitive, inductive, eddy-current and similar sensors for measurement of temperature, displacement, pressure, torque etc. The gain achieved depends on the transformer voltage ratio, n. Unlike the usual transformer application for voltage raise (gain) where the gain is proportional to n, in this circuit, the high gain is achieved with n close to 1. This is due to positive feedback introduced into the circuit. Transformers with voltage ratios close to 1 exhibit much less leakage and smaller losses which can degrade the (ideal) gain. With current on-chip transformers or miniature transformers available on the market, the practical gain can reach 20 dB. The circuit can be easily integrated into various MEMS sensors. As the circuit is entirely passive, its application extends far beyond the usual semiconductor temperature limits. Depending on the transformer technology, the circuit can be used in a very cold (e.g. cryogenic) or very hot environment (e.g. steam and gas turbines, jet engines, rockets, down-hole drilling, etc.) or exposed to nuclear radiation.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus