Pregled bibliografske jedinice broj: 1118032
The 2019 M6.4 Durrës (Albania) eq damage to infilled RC frames in correlation with shake table experiments
The 2019 M6.4 Durrës (Albania) eq damage to infilled RC frames in correlation with shake table experiments // 1st Croatian Conference on Earthquake Engineering - 1CroCEE Conference Proceedings / Lakušić, Stjepan ; Atalić, Josip (ur.).
Zagreb: Građevinski fakultet Sveučilišta u Zagrebu, 2021. str. 973-975 doi:10.5592/CO/1CroCEE.2021 (predavanje, međunarodna recenzija, prošireni sažetak, znanstveni)
CROSBI ID: 1118032 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The 2019 M6.4 Durrës (Albania) eq damage to
infilled RC frames in correlation with shake
table experiments
Autori
Penava, Davorin ; Abrahamczyk, Lars ; Al Hanoun, Muhammad Hisham ; Schwarz, Jochen
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, prošireni sažetak, znanstveni
Izvornik
1st Croatian Conference on Earthquake Engineering - 1CroCEE Conference Proceedings
/ Lakušić, Stjepan ; Atalić, Josip - Zagreb : Građevinski fakultet Sveučilišta u Zagrebu, 2021, 973-975
ISBN
978-953-8168-47-5
Skup
1st Croatian Conference on Earthquake Engineering (1CroCEE)
Mjesto i datum
Zagreb, Hrvatska, 22.03.2021. - 24.03.2021
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
M6.4 Durrës (Albania) earthquake ; damage survey ; masonry infilled RC frame ; correlation ; shake table experiment
Sažetak
On November 26th 2019 the Mw = 6.4 earthquake struck the north-central Albania causing casualties and severe damage (IEMS = VIII) to the built environment, and in particular to the city of Durrës. This earthquake occurred not long after the Mw = 5.6 earthquake on September 21, 2019. In January 2020, the American Concrete Institute (ACI) Technical Committee 133 Disaster Reconnaissance task group inspected the damaged buildings in the city of Durrës. The primary goal was to observe the damage to masonry infilled RC frame buildings built after 1990’s, designed and constructed in compliance with contemporary structural codes. The most distinguished was in-plane (IP) and out-of-plane (OoP) very heavy damage or destruction of masonry infill walls – local damage grades 4 or 5 – in compliance with EMS- 98 scale. Damage to the RC frame structure was negligible to slight – local damage grades 1 or 2.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo, Temeljne tehničke znanosti
POVEZANOST RADA
Projekti:
IP-2013-11-3013 - Uokvireno ziđe - kompozitni nosivi sustav kod armirano-betonskih zgrada (FRAmed-MAsonry) (Sigmund, Vladimir, HRZZ - 2013-11) ( CroRIS)
Ustanove:
Građevinski i arhitektonski fakultet Osijek
Profili:
Davorin Penava
(autor)