Pregled bibliografske jedinice broj: 111638
Pulsed remote field technique in ferromagnetic tube wall thickness and inner diameter measurement
Pulsed remote field technique in ferromagnetic tube wall thickness and inner diameter measurement // Metrology in the 3rd Millennium / Ilić D., Boršić M., Butorac J. (ur.).
Zagreb, 2003. str. 912-916 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 111638 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Pulsed remote field technique in ferromagnetic tube wall thickness and inner diameter measurement
Autori
Vasić, Darko ; Bilas, Vedran ; Ambruš, Davorin
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Metrology in the 3rd Millennium
/ Ilić D., Boršić M., Butorac J. - Zagreb, 2003, 912-916
Skup
XVII IMEKO World Congress
Mjesto i datum
Dubrovnik, Hrvatska, 22.06.2003. - 27.06.2003
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
pulsed eddy current; pulsed remote field technique; wall thickness and inner diameter measurement
Sažetak
In conventional applications of the remote field eddy current technique, a probe with low frequency sinusoidal excitation is used for measurement of ferromagnetic tube wall thickness. An additional probe with high frequency excitation is required for measurement of the tube inner diameter (electrical caliper). In this paper, this is illustrated with results of finite element analysis. However, the waveform of the pulse driving current and shorter probe length potentially allow the measurement of the inner diameter and the wall thickness with the same probe. We present results of our experiments on ferromagnetic tubes with internal and external defects that confirm applicability of the pulsed remote field technique for measurement of the both quantities.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb